Laserfiche WebLink
• � • e e • - ' , � - <br />2012 Washington State Energy Code Compiiance Forms for Commercial Buildings including R2 8 R3 over 3 stories and all R1 Revised Jan 2014 <br />ProjectAddress rue21-EverettMall Date 4/1/2016 <br />The following information is necessary to check a permit application for compliance xdth the lighfing, motor, and iransformer requirements in the <br />Washington State Energy Code, Commerciai Provisions. <br />Applicability Location in Building Department <br />(yes,no,na) Code Seciion Component Compliance information required in permit documeMs Documenis Notes <br />Provide fixfure schedule with fixture types, lamps, baliasts, and <br />rated watts per fixture; <br />C4D5.5,1 Identify spaces eligible for lighting power e:cemptlon on plans <br />C405.5.1.1 Total connected and in compliance forms; <br />Yes C405.5.1.2 --- _._—_ �_ _ _ <br />inierior lighting power ldenti li htin e ui ment eli ible for exem iion in fixlure <br />C405.5.1.3 fY 9 9 q P 9� P <br />C405.5.1.4 schedule and in compliance forms; <br />Indicate that exem pt lighting equi pment is in addition to general <br />area lighting and is controlled independently <br />Yes C405.4 Exit signs Provido exit sign types and rated watts per ftxture in fixture <br />schedule (maximum 5 watts per fixture) <br />C405.10 Cooler and freezer For lighting in walk-in coolers and freezers, and refngerated <br />NA warehouse coolers and freezers, provide rated lamp eNicacy (in <br />C405.11 lighti n g <br />lumens perwatt) in flxture schedule <br />Lighting Power Calculatfon - Indicate compiiance path taken <br />Complete required compliance forms - pro��osed wattage per <br />xA C405.5.2 Building Area Method buiiding area does not exceed maximum allowed wattage per <br />building area. Identiiylocations of building areas on plans <br />Complete required compliance forms-total proposad wattage <br />xA C405.5.2 Space-E3y-Space does not exceed maximum allowed wattage. Identify locations <br />Method of space types on plans, including retail display areas as <br />appl icabl e <br />EXTERIOR LIGHTING POWEf� & EFFICACY 5ection C405.6 <br />Arovide fixture schedule with fixture types, lamps, ballasis, and <br />rated watts perfixture; <br />Total connected <br />�A C405.6.2 exterior IighUng Identify exterior applications eligible for lighting pawer <br />power exemption on plans and In compliance forrris; <br />Indlcate that exempt extenor lighting is conlrolled independentl y <br />from non-exem pt exteri or I ig hti ng <br />xA Table , <br />C405.6.2('1) E�erlor lighting zone Indicate building e�eriorlighting zone as defined by the AHJ <br />Exterior buildin For building grounds fixtures rated at greater than 100 w atts, <br />xA C405.6.'I grounds lighting Provide rated lamp efficacy (in lumens pervvatt) in fixture <br />schedule <br />Extenor li htin Complete required compliance form - proposed wattage tor <br />NA C405.62 Powercaculat ons exterior lighting pius base site allowed does not exceed <br />maximum allowed <br />MOTORS & TRANSFORMERS (Secfions C405.8, C4Q5.9) <br />xA C405.8 Electric Motors For mators not part of an HVAC system, provide electric motor <br />schadule on efectrical plans with hp, rpm, and rated efficiency <br />C405.9 Transfarmers Provide distribution transformer schedule on elecTrical plans <br />with transformer size and efficiency <br />If ^.... ... ..,.i..,.a,.a c__ __ . . . � , .. <br />