My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9506 7TH AVE SE 2017-04-10
>
Address Records
>
7TH AVE SE
>
9506
>
9506 7TH AVE SE 2017-04-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2017 7:58:09 AM
Creation date
12/13/2016 3:49:38 PM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
9506
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
July 26, 2013 <br />PUBLIC WORKS <br />Mr. Griffin Campbell <br />Eastlake Community Church <br />PO Box 12028 <br />Everett, WA 98206 <br />Project: Eastlake Community Church <br />Job Address: 9506 7th Ave SE <br />Plan Review: B1307-015 <br />RE: Incomplete submittal (revisions update) <br />_ _ ..; <br />i,.� . . i. � l .+- i 1 t i <br />i ��2�/ l3 <br />��..__. : . � _ � _ _. <br />Dear Mr. Campbell, <br />In response to the revisions submitted, the plans have been examined and you are advised that this is an <br />incomplete submittal. The permit application cannot be reviewed for corrections until the following items are <br />submitted. <br />Please submit two sets of revised plans and details with a response letter to each item in this letter, indicating <br />how it is resolved on the plan set. <br />General: <br />1. Since the building is larger than 4000 square feet, and the revisions affect life safery and structural <br />systems, architectural revisions are required for this tenant improvement permit, and those drawings <br />should be stamped by a licensed architect, per RCW 18.08.410 (7). � <br />2. To indicate what is being proposed as new workon this permit, please revise the drawings as follows: <br />a. Please indicate new work with dark lines. Existing work should be indicated as light lines, <br />and demolition work should be indicated with dashed lines. This includes ceilings, wall sections, <br />doors, stairs, ramps, structure, and toilet rooms, and any other revision where a building permit <br />is required, per IBC section 105.1. <br />b. New walls should be targeted on the plans to detailed wall sections. <br />3. The area of new work should be identified with a scoping bubble on the overall floor plan. <br />a. Work not included should be omitted from drawings, if it not part of the current scope of new <br />work. Historical drawings that indicate "as-is" construction, prior to the tenant improvement, <br />should not be included in the permit set. <br />b. Work included on this permit should have room numbers, room names, door numbers, and <br />wall targets on the drawings for easier reference. <br />c. The architectural drawings submitted are dated 1979, which show areas of work as existing <br />that have already been shown as demolished on the recent permit B1305-024. <br />Structural: <br />1. Based on the assembly occupant load, the lateral design of the floor replacement for an increased load <br />should be shown to meet the requirements for occupancy category III, per IBC 1604. Structural <br />components of the load path must be detailed and included in the construction documents. <br />
The URL can be used to link to this page
Your browser does not support the video tag.