DESIGN CRITERIA: <br />1. THE STRUCTURAL DESIGN OF THIS PROJECT IS IN ACCORDANCE WITH <br />THE IN7ERNATIONA� BUILDING CODE 2012 WITH WASHINGTON STATE <br />BUILDING CODE AMENDMENTS (2012) <br />2. DESIGN LOADS: <br />DESIGN DATA FOR MARYSVILLE, WASHMGTON <br />-ROOF SNOW LOAD N/A (NOT A ROOFTOP SOLUTION) <br />-BASIC WIND SPEE� 85 MPH <br />-WIND EXPOSURE C <br />-SEISMIC ZONE D <br />CONCRETE NOTES: <br />1. ALL CONCREfE CONSTRUCTION SHALL BE IN ACCORDANCE WITH <br />ACI-318. <br />2. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AN� PLACED IN <br />ACCORDANCE WITH CHAPTER 19 OF THE 2009 IBC WITH WASHINGTON <br />AMENDMENTS. STRENGTHS AT 28 DAK AND MIX CRITERIA SHALL BE <br />AS fOLLOWS UNLESS OTHERWISE NOTED. <br />28 DAY STRENGTHS W/C RATIO MINIMUM CEMENT CONTENT <br />(f'c) PER CUBIC YARD <br />2,500 PSI G.45 5 1/2 SACKS <br />CEMENT SHALL BE ASTM C150, PORTLAND CEMENT NPE II U.N.O. <br />3. THE GENERAL CONTRACTOR SHALL SUPERVISE AND BE RESPONSIBLE <br />FOR THE METHODS AND PROCEDURES OP CONCREfE PLACEMENT. <br />4. ALL CONCRETE WITH SURFACES EXPOSED TO WEP.THER SHALL BE <br />AIR-ENTRAINED WITH AN AIR-ENTR4INING AGENT CONFORMING TO ASTM <br />C260, C494, C618, C989 AND C1017. CONCREfE E%POSED TO <br />FREEZING AND THAWING WHILE MOIST SHALL BE AIR ENTRAINED IN <br />ACCORDANCE WITH ACI 318, SECTION 4.4.1. <br />5. REINFORCING SiEEL SHALL CONFORM TO AST�1 A615 (INCLUDING <br />SUPPLEMENi S1), GR4DE 6Q fy=60,000 PSL EXCEPTIONS: ANY BARS <br />SPECIFlCALLY SO NOTED ON THE DRAWINGS SHALL BE GRADE 40, <br />fy=40,000 P51. GRADE 60 REMFORCING BARS INDICATED ON ORAWINGS <br />TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING <br />COMPLYING WITH ASTM A615(51) MAY BE WELDED ONLY IF MATERI,4� <br />PROPERtt REPORTS INDICATING CONFORMANCE WITH WELDMG <br />PROCEDURES SPECIPIED IN a.w.5. D14 ARE SUBMITTED. <br />6. REWFORCING STEEL SHALL BE DEfAILED (MCLUDING HOOKS AND <br />BENDS) IN ACCORDANCE WITH AC7 315 AND 318. LAP ALL <br />CONTINUOUS REINFORCEMENT AT LEAST }0 6AR DIAMEfERS OR A <br />MINIMUM OF 2'-0". PROVIDE CORNER BARS AT ALL WALL AND FOOTING <br />WTERSECTIONS. LAP CORNER BARS AT LEAST 30 BAR DIAMEfERS OR <br />A MINIMUM OF 2'-0". LAP ADJACENT MATS OF WELDED WIRE FABRIC A <br />MINIMUM OF 8" AT SIDES AND ENDS. <br />7. WELDED WIRE FABRIC SHALL CONFORM TO lS7M A-185. <br />B. SPIRAL REMFORCEMENT SHALL BE PlAIN WIRE CONFORMING TO ASTM <br />A615, GR4DE 60, fy=60,000 PSI. <br />9. REWFORCING PARTIALLY EMBEDDED IN CONCRETE SHALL NOi BE RELD <br />BENT UNLESS SPECIFICALLY SO DETNLED OR APPROVED BY THE <br />CONSULTANT. <br />70. CONCRETE PROTECTION (COVER) FOR REWFORCING STEEL SNALL BE AS <br />FOLLOWS: <br />-FOOTINGS AND OTHER UNFORMED <br />SURFACES, EARTH FACE 3" <br />-FORMED SURFACES E%POSED (�'6 BARS OR LARGER) 2" <br />TO EARTH OR WEATHER (�'5 BARS OR SMALLER) t-1/2" <br />-SLABS AND WALLS (WTERIOR FACE) 3/4' <br />11. BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS. <br />12. ANCHOR BOLTS TO CONFORM TO ASTM A307. <br />13. NON-SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED <br />MANUFACTURER AND SHALL BE MI%ED AND PLACED IN STRICT <br />ACCORDANCE WITH THE MANUFACTURER'S PUBUSHED RECOMMENDATIONS. <br />GROUT STRENGTH SHALL BE AT LEAST E�UAL TO THE MATERIAL ON <br />WHICH IT IS PLACED (3,�OD PSI MINIMUM�. <br />14. ALL EXPANSION ANCHORS TO BE HILTI BRAND. ADHESIVE ANCHORS <br />REQUIRE TESTING TO CONFlRM CAPACITY UNLESS WANED BY ENGINEER <br />AND LOCAL JURISDICTION. <br />STRUCTURAL STEEL NOTES: <br />7. SHOP DRAWINGS FOR STRUCTl1RAL STEEL SHALL BE SUBMITTED TO AT&7 AND THE <br />CONSULTANT FOR REVIEW PRIOR TO FABRICATION. <br />2. STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION (INCLUDING FIELD WELDING, <br />HIGH STRENGTH FIELD BOLTING, EXPANSION BOLTS, AND THREADED EXPANSION <br />ANCHORS) SHALL BE BASED ON 7HE A.I.S.C. 'SPECIFICATION FOR THE �ESIGN, <br />FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" L4TEST EDITION. <br />SUPERVISION SHALL BE IN ACCORDANCE WITH 2O03 IBC CHAPTER 22, BY A QUALIFIED <br />TESTING AGENCY DESIGNATE� BY THE CONSULTANT. THE CONSULTANT SHALL BE <br />FURNISHED WITH A COPY OF ALL INSPECTION REPORTS AND TEST RESULTS. <br />3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REOUIREMENTS: <br />4. TYPE OF MEMBER <br />A. WIDE FLANGE SHAPES ASTM A992, GRADE 50 <br />A. OTHER SHAPES, PLATES, ANGLES, AND RODS ASTM AJ6, Fy 36 KSI <br />B. SPECIAL SHAPES AND PLATES ASTM A572, Fy 50 KSI <br />C. PIPE COLUMNS ASTM A53, Fy 35 KSI <br />D. STRUCTURAL TUBING ASTM A500, Fy 46 KSI <br />E. ANCHOR BOLTS ASTM A307 <br />F. CONNECTION BOLTS ASTM A325 TWIST-OFF-NPE <br />5. HOT DIP GALVANIZE AFTER FABRICAiION PER A123/A123M-00 ALL STEEL EXPOSED TO <br />WEATHER AND WHERE NOTED. <br />6. ALL WELDING SHA�L BE IN CONFORMANCE WITH A.I.S.C. AND AWS STANDAftDS AND SHALL <br />BE PERFORMED BY ANSI/AWS D1.1 CERTIFIED WELDERS USING E70 %% ELECTRODES. <br />ONLY PRE�UALIFIED WELDS (AS DEFINED BY AWS) SHALL BE USED. WELDING DF GRADE <br />60 REMFORCING BARS (IP REQUIRED) SHALL BE PERPORMED USING LOW HYDROGEN <br />ELECTRODES. WELDING OF GRADE 40 REWFORCWG BARS (IF REQUIRED) SHALL BE <br />PERFORMED USING E70 XX ELECTRODES. WELDING WITHIN 4" OF COLD BENDS IN <br />REINFORCWG STEEL IS NOT PERMITTED. SEE REINFORCMG NOTE FOR MATERIAL <br />RE UIREMENTS OF WE ARS. <br />Q LDED B <br />7. COLD-FORMED STEEL FR4MING MEMBERS SHALL BE OF THE SHAPE, SIZE, AND GAGE <br />SHOWN ON THE PLANS. PROVIDE MINIMUM SECTION PROPERTIES INDICATED. ALL <br />COLD-FORMED STEEL FRAMING SHALL CONFORM TO THE A.I.S.S. "SPECIFICATION FOR <br />THE DESIGN OF COLD-PORMED STEEL STRUCTURAL MEMBERS." <br />8. BOLTED CONNECTIONS SHALL USE BEARING NPE ASTM AJ25 BOLTS (3/4" DIA.) AND <br />SHALL HAVE A MINIMl1M OF iW0 BOLTS UNLESS NOTED OTHERWISE. <br />9. NON-STRUCTl1RAL CONNECTIONS POR STEEL GRATING MAY IJSE 5/8' DIA. lSTM A307 <br />BOLTS UNLESS NOTED OTHERWISE. <br />10. (UNLESS NOTED OiHERW6E). PREPARATION AND PAINTING SHALL BE IN ACCORDANCE <br />WITH THE SPEGPICATION AND IN ACCORDANCE WITH THE PAINT MANUFACTURERS WRITTEN <br />WSTRUCTIONS. <br />11. ALL WELDS TO BE 1/4" RLLE7 UNLESS NOTED OTHERWISE. <br />12. TOUCH UP ALL FlELD DRILLING ,WELDING AND CUT SURfACES WITH 2 COATS OF <br />GALVACON (ZINC RICH PAINT) OR APPROVED EOUAL. <br />TOWER/POLE NOTES: <br />1. VERIFICATION THAT THE EXISTING TOWER/POLE CAN SUPPORT THE PROPOSED ANTENNA <br />LOADING IS TO BE DONE 8Y OTHERS. <br />2. PROVIDE SUPPORTS FOR TNE ANTENNA COAX CABLES TO THE ELEVATION OF ALL INITIAL <br />AND fUTURE AMENNAS. ANTENNA COAX CABLES ARE TO BE SUPPORTED ANO <br />RESTRAWED AT THE CENTERS SWTABLE TO THE MANUFACTURER'S RE�UIREMENTS. <br />NOTE <br />STRUCTURAL DRAWINGS AND NOTES SHALL TAKE PRECEDENCE <br />OVER ALL DR4WING5 AND NOTES. <br />SPECIAL INSPECTIONS: <br />1 <br />2. <br />3. <br />CONTRACTOR SHALL PROVIDE REQUIRED SPECIAL INSPECTIONS PERFORMED BV AN <br />INDEPENDENT INSPECTOR, APPROVED BY AThT AND THE LOCAL JURISDICTION, AS <br />REOUIRED BY THE 2009 IBC SECTION 1704 WITH WASHINGTON AMENOMENTS FOR THE <br />FOLLOWING: <br />A. CONCREfE: PROVIDE SPECIAL WSPECTION PER 7704.4 <br />i. TAKE CONCREfE TEST SPECIMENS DURING THE PLACING OF STRUCTURAL <br />REINFORCING AND STRUCTURAL CONCRETE. EXTERIOR AND INTERIOR SL485 ON <br />GR4DE ARE NOT SiRUCiURAL ELEMENiS. <br />n. VERIFY REINFORCING SIZE, PLACEMENT, AND GR4DE. <br />B. BOLTS AND ANCHORS IN CONCREfE: <br />�. HOLDDOWN ANCHORS BOLTS: INSPECT SIZE, LENGTH, HOOK AND TIE TO <br />REINFORCING. <br />u. ADHESIVE ANCHORS: INSPECT HOLE S12E, DEPTH, CLEANLMESS, AND <br />INSTALLATION PER MANUFACTURES RECOMMENDATIONS. <br />C. WELDING: <br />�. VISUALLY INSPECT ALL STRUCTURAL FIELD AND $HOP WELDING. <br />u. THE SPECIAL INSPECTOR NEED NOT TO BE CONTINUOUSLY PRESENT DURING <br />WELDING. PROVI�ED 7HE MA7ERIALS, QUALIFICATIONS OF WELDING PROCEDURES <br />AND WELDERS ARE VERIFIED PRIOR TO THE START OF WORK; PERiODIC <br />INSPECTIONS ARE MADE OF WORK IN PROGRESS; AND A VISUAL INSPECTION <br />OF ALL WELDS IS MADE AFTER COMPLETION OR PRIOR TO $HIPMENT OF SHOP <br />WELDING. <br />PROVIDE SPECIAL INSPECTIONS FOR OTHER ITEMS NOTED ON DRAWINGS TO CONFIRM <br />COMPLIANCE WITH CONTR4CT DOCUMENTS. <br />THE SPECIAL INSPECTOR SHALL PROVIDE A COPv OF THE REPORT TO THE OWNER, <br />ARCHITECT, STRUCTUR4L ENGINEER, CONTRACTOR, AND BUILDING OFFICIAL. <br />ABBREVIATED ROOF TOP SAFETY PROCEDURES <br />(WHEN APPLICABLE: <br />FALL PROTECTION MEfHOD$ AND EQUIPMENT ROOF TOP INSTALLATIONS. <br />L FALL PROTECTION METHODS TO BE PER FEDERAL, STATE, LOCAL, OSHA, AT&T AND <br />OWNER REQUIREMENTS. <br />2. FOR WORK IS BEING PERFORMED WITHIN 25' OF AN UNPROTECTED ROOF EDGE, THE <br />CONSTRl1CTI0N SUPERVISOR SHALL DESIGNATE A TRAINED SAFEfI' MONITOR TO OBSERVE <br />THE MOVEMENTS ANO ACTIVITIES OF THE CONSTRUCTION WORKERS. <br />3. SAFEiY MONITOR SHALL WARN CONSTRUCTION WORKERS OF HAZARDS (LE., BACKING UP <br />TOWARD A ROOF EDGE, ETC.) OR UNSAFE ACTIVITIES. THE SAFEIY MONITOR MUST BE ON <br />THE SAME ROOF AND WITHIN VISUAL AND VERBAL DISTANCE OF THE CONSTRUCTION <br />WORKERS. <br />4. CONSTRUCTION INVOLVING WORKERS TO APPROACH WITHIN 6' OR LESS OF AN <br />UNPROTECTED ROOF E�GE, REQUIRES WORKERS TO USE SAFEfY LWE. <br />5. SAFEiY LINE SHALL BE MINIMUM 7/2" DIAMETER NYLON, WITH A NOMINAL TENSILE <br />STRENGTH OF 5400 LBS. <br />6. SAFEfY LINE SHALL BE ATTACHE� TO A SUBSTANTIAL MEMBER OF THE STRUCTURE. <br />7. SAFEfY LINE LENGTH SHALL BE SET ALLOWING CONSTRUCTION WORKER TO REACH EDGE <br />OF ROOF, BUT NOT BEYOND. <br />8. SAFEiY BELTS SHALL BE WORN 8Y ALL CONSTRUCTION WORKERS. <br />9. MONTHLY SAFEfI'�NSPECTION AND MAWTENANCE OF THE FALL PROTECTION EQUIPMENT <br />SHALL OCCUR BY THE SAFEiY COMMITTEE REPRESENTATNES, INCLUDING: <br />INSPEC710N OF CONSTRUCTION AREA FOR HAZARDS <br />USE OF AN WSPECTION CHECKLIST <br />INTERVIEWING COWORKERS REGARDING SAFEfY CONCERNS <br />REPORTING AND DOCUMENTING ANY HAZARDS <br />REPORTING HAZARDS TO THE SAFEIY COMMITTEE FOR CONSIDERATION <br />POSTING RESULTS OF INSPECTION AND ANY ACTION TAKEN <br />RECEIVING AN UNB:ASED REVIEW OF ONE'S OWN WORK AREA BY ANOTHER <br />COWORKER SAFEfY REPRESENTATIVE <br />REFER TO ROOFTOP WORK AREA SAFEIY PROTOCOL NATIONAL ASSOCIATION OF TOWER <br />ERECTORS 2000 PUBLICATION <br />REFERENCED OSHA REGUlAT10N/STANDARDS SHALL BE REVIEWED BY TOWER ERECTORS, <br />EQUIPMENT INSTALLERS, AND TOWER/ROOF TOP CONTRACTORS/SUBCONTR4CTORS <br />29 CFR 1926.500 - SCOPE, APPLICATION, AND DEFINITIONS <br />29 CFR 1926.501 - DUTY TO HAVE PALL PROTECTION <br />19 CFR 1926.502 - FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES <br />SYMBOLS AND ABBREVIATIONS <br />A/C AIR CONDITIONING HORZ HORIZONTAL <br />AGL ABOVE RNISH GRADE HR HOUR <br />APPROX APPROXIMATELY HT HEIGHT <br />HVAC HEATING <br />BLDG BUILDING VENTILATION <br />BLK BLOCKING AIR CONDITIONING <br />CLG CEILING ID INSIDE DIAMEfER <br />CLR CLEAR IN INCH <br />CONC CONCRE7E INFO INFORMATION <br />CONST CONSiRUCT10N INSUL INSUL4TION <br />CONT CONTINl1DUS MT INTERIOR <br />IBC INTERNATIONAL <br />DBL DOUBLE BWL�ING CODE <br />DIA DIAMETER <br />DIAG �IAGONA� LBS POUNDS <br />DN DOWN <br />DET DETAIL MA% MAXIMUM <br />DWG DRAWING MECH MECHANICAL <br />MTL METAL <br />EA EACH MFR MANUFACTURE <br />ELEV ELEVATION MGR MANAGER <br />ELEC ELECiRiCAL MIN MINIMUM <br />EO EQUA! MISC MISCELLANEOUS <br />EOUIP EOUIPMENT <br />EXT ExTER10R NA NOT APPLICABLE <br />NIC NOT IN CONTRACT <br />FIN FINISH NTS NOT TO SCALE <br />FLUOR FLOURESCENT <br />FLR FLOOR OC ON CENTER <br />FT F00T OD OUTSIOE DIAMEfER <br />GA GAUGE <br />GALV GALVANIZED <br />GC GENER4L CONTR4CTOR <br />GRND GROUND <br />GYP BD CYPSUM WALL BOARD <br />- T - TELEPHONE <br />- P - POWER <br />- G - GROUND WIRE <br />- COA%- COA%IAL CABLE <br />� ANTENNA <br />� CENTERLME <br />�E� EXIS7ING <br />�N� NEW <br />� DETAIL NUMBER <br />SHEET NUMBER <br />PLYWD PL7WOOD <br />PROJ PROJECT <br />PROP PROPERTY <br />PT PRESSURE TREATED <br />REQ REQUIRED <br />RM ROOM <br />RO ROUGH OPENING <br />SHT SHEET <br />SIM SIMIIAR <br />SPEC SPECIFICATION <br />SF SOUARE F00T <br />55 SiAINLESS STEEL <br />STL S7EEL <br />STRUCT STRUCTURAL <br />STD STUD <br />SUSP SUSPENDED <br />THRU THROIJGH <br />TNNG TINNED <br />NP ttPICAL <br />UNO UNLESS NOTED <br />OTHERWISE <br />VER7 VERTICAL <br />VIF VERIfY W FICLD <br />W� WITH <br />�y�p WITHOUT <br />yyp WATER PROOF <br />N <br />U <br />G <br />Q <br />� <br />� <br />� <br />J °' <br />QU <br />N � <br />LL � <br />W� <br />� <br />Z`� <br />� <br />W'n °' <br />{..i � <br />'19401 40TH AVE. W., SUITE 304 <br />LYNNWOOD, WA98036 <br />PHONE: (425) /40-6392 <br />FAX:(425)224-16'I4 <br />N/W W.CAMPASSOC.COM <br />DATE: 12/22/15 <br />DRAWN BY: ATD <br />CHECKED BY: GA <br />REVISIONS <br />ISSUED FOR <br />' REGISTERED <br />7 ARCHI ECT <br />u�PIAU L N I <br />ATE OF ASHINGTON <br />\ I2/2��/2nli <br />SN30-PINEHURST <br />2408 39TH STREET <br />EVEREI7, WA 98201 <br />SHEET TITLE <br />GENERALNOTES <br />SHEET NUMBER <br />G-2.0 <br />�� <br />