My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1327 112TH ST SE 30 10 WEIGHT LOSS FOR LIFE 2018-09-19
>
Address Records
>
112TH ST SE
>
1327
>
30 10 WEIGHT LOSS FOR LIFE
>
1327 112TH ST SE 30 10 WEIGHT LOSS FOR LIFE 2018-09-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2018 1:44:10 PM
Creation date
12/14/2016 2:19:34 PM
Metadata
Fields
Template:
Address Document
Street Name
112TH ST SE
Street Number
1327
Tenant Name
30 10 WEIGHT LOSS FOR LIFE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
z012 Washington State Ene Code Compliance Forms for Commercial, Gro R1, and > 3 story R2 and R3 <br />• • • � • • ' - ' <br />2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 <br />Project Address 3o-io WEIGHT i.oss Fox Li� Date 2�21/2014 <br />The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements <br />in the 2012 Washington State Nonresidential Energy Code. <br />Applicability Code Location Building Department <br />(yes, no, n.a.) Section Component Information Required on Plans Notes <br />LIGHTING CONTROLS (Section C405.2) <br />� C405.2.1 Manual lighting Lighting control schedule with type, locations served, 50% � <br />— controls lighting reduction method <br />Lighting systems automatic shut-off capability - indicate <br />C405.2.2.1 Automatic time method and location served on plans. Note locations where � <br />switch controls automatic shutoff is provided by other method (occupancy <br />sensor, daylight controls, etc) <br />Override switching Schedule with locations served - no single override switch � <br />exceeds an area of 5,000 SF <br />C405.2.2.2 Occupancy sensors Schedule of locations served A2 <br />C405.2.2.3 Daylight zones <br />Vertical fenestration Primary and secondary daylight zone areas indicated on <br />plans <br />Skylights Skylight daylight zone areas indicated on plans <br />405.2.2.3. Daylight zone Lighting control schedule with dimming method and locations <br />controls served - no single dayli ht control zone exceeds 2,500 SF <br />Specific application Specific application lighting controls are independent of <br />C4052.3 controls general area lighting and controls for other lighting <br />applications <br />Means of egress Lighting control schedule with method and locations served. � <br />lighting Note luminaires that function as both normal and egress. <br />Display lighting Lighting control schedule with type and locations served <br />Accent lighting Lighting control schedule with type and locations served <br />Hotel/motel guest Lighting control schedule with type and locations served <br />rooms <br />Supplemental task Lighting control schedule with type and locations served <br />li htin <br />Non-exempt lighting Lighting control schedule with type, applications served and <br />equipment locations <br />Non-exempt lighting Lighting control schedule with type, applications served and <br />equipment locations <br />C4052.4 Exterior lighting Lighting control schedule with type, features and location <br />controls served <br />INTERIOR LIGHTING POWER Section C405.5 <br />C405.5.1 Total connected Schedule with fixture types, lamps, ballasts, watts per fixture <br />li hting power <br />Space exceptions Space exceptions taken noted on plans or compliance form <br />Lighting equipment Equipment exceptions taken noted on plans or compliance <br />exceptions form <br />C405.5.2 Lighting power <br />calculations <br />Building Area Method Compliance form completed — proposed wattage per building <br />area does not exceed maximum allowed wattage <br />Space-By-Space Compliance form completed — total proposed wattage does <br />Method not exceed maximum allowed watta e <br />C405.4 Exit signs All internally illuminated exits sign are < 5 watts per side <br />EXTERIOR LIGHTING POWER Section C405.6 <br />C405.6.2 Total connected Schedule with fixture types, lamps, ballasts, watts per fixture <br />li htin power <br />E�erior application Exterior application exceptions taken noted on plans or <br />exceptions compliance form <br />Lighting power Compliance form completed — proposed wattage for exterior <br />calculations li htin plus base site allowed does not exceed max. allowed <br />
The URL can be used to link to this page
Your browser does not support the video tag.