My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3414 WETMORE AVE 2017-01-13
>
Address Records
>
WETMORE AVE
>
3414
>
3414 WETMORE AVE 2017-01-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2017 9:38:13 PM
Creation date
12/22/2016 10:34:47 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
3414
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• F�ne•�iTe�A�arms <br />by Honeywell <br />GENERAL <br />The Fire•Lite MS-5210UD is a 24-volt, ten-zone fire alarm <br />control panel with built-in communicator and remote-site <br />Upload/Download capability (requires panel software revi- <br />sion #MS52103.0 or greater). The integral communicator <br />transmits event information (alarms, troubles, supervi- <br />sories, faults, etc.) to a UL listed central station. Select- <br />able transmission formats allow the MS-5210UD to com- <br />municate to virtually all central stations. <br />FEATURES <br />• Ten programmable Initiating Device Circuits (zones). <br />Each zone may be programmed for: <br />✓Two-wire smoke detectors. <br />✓ N.O. contact devices (pull, heat). <br />✓ Four-wire smoke detectors. <br />✓ Waterflow operation (silenceable or nonsilenceable). <br />✓ Supervisory operation. <br />✓ Auto-reset supervisory operation. <br />✓ Remote switch for Reset, Drill, Silence and Acknowl- <br />edge. <br />✓ Auto-reset or latching, critical and noncritical process <br />monitoring. <br />• Zones programmed for process monitoring require a <br />contact closure for activation and can be used to monitor: <br />✓ Temperature (high/low temp). <br />✓ Water level. <br />✓ Refrigeration. <br />✓ Gas detection. <br />✓ Tamper (non-fire). <br />✓ Loss of air flow. <br />✓ Open/Close. <br />• Two built-in, Class B(Style Y) Notification Appliance <br />Circuits (NACs) — expandable to four. <br />• Notification Appliance Circuits may be programmed: <br />✓ Silenceable. <br />✓ Non-Silenceable (a strobe circuit can keep flashing <br />after the panel is silenced). <br />✓ Auto-Silence (program 5 to 30 minutes). <br />✓ Silence Inhibit (60 seconds). <br />✓ Coding (March Time, Temporal, California). <br />• 3.0 Amps of Notification Appliance power, expandable to <br />6.0 amps (meets the critical power requirements for ADA <br />and UL-1971 devices). <br />• Two built-in, fully programmable Form-A relays - expand- <br />able to four with two Form-C relays. <br />• Dual-linerotary-orTouch-ToneO-dialDACTinterfacesto <br />public telephone network (leased phone lines are not <br />required). <br />• 24-Volt operation. <br />July 12, 2004 DF-51492 • A3-400 <br />MS-5210UD�C/E� <br />Fire Alarm Control Panel with built-in DACT <br />and remote-site Upload/Download capabilitp <br />Section: Control/Communicators <br />�� California <br />M EA ,���� State Fire <br />� Marshal <br />� `. 122-96-E �`�='�',, 7165-0075:177 <br />���_H <br />LISTED <br />S5624 <br />FCC <br />1 W6USA- <br />20723-AL-E <br />INDUSTRY <br />CANADA <br />21325785A <br />FM <br />APPROVEQ <br />MS-5210UD <br />m <br />� <br />0 <br />N <br />E <br />• Built-in voltmeter measures: <br />✓ Zone voltage. <br />✓ Primary AC line voltage. <br />✓ Battery voltage. <br />✓ Notification Appliance Circuit(s) voltage. <br />✓ Resettable 24-volt power. <br />• Surface Mount Technology (SMT). <br />• Fully programmable via built-in keypad (no costly exter- <br />nal programmers necessary). <br />• Complies with NFPA 72 (Local, Central Station and <br />Remote Station �DACT only - not polarity reversal] Fire <br />Alarm Systems). <br />• Reporting Formats include Ademco Contact ID and 14 <br />others. <br />• Integral battery charger for up to 60 hours of standby <br />power. <br />• Fuseless, power-limited technology meets new UL power- <br />limiting requirements, effective May 1, 1995. <br />• Programmable Alarm Presignal Timer, Alarm Verifica- <br />tion Timer and Optional Trouble Reminder. <br />• Single-person walk test with 256-event walk-test buffer. <br />• Fire drill function. <br />• Zone disable capability (software). <br />• 256-Event history buffer with time and date stamp, stored <br />in permanent memory. <br />• Accurate real-time clock/calendar. <br />This document is not intended to be used for installation purposes. We try to keep I�O 9001 <br />our product information up-to-date and accurate. We cannot cover all specific <br />applications or anticipate all requirements. All specifications are subject to change <br />without notice. For more information, contact Fire•Lite Alarms, One Fire-Lite Place, • <br />Northford, Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699�105, ENCINEE6111� 8 MAIVUFACIURIN6 <br />Website: www.firelite.com Q U A L I T Y S Y S i E M S Made in the U.S.A. <br />� �DF-51492 • 07/12/04 — Page 1 of 3 !� <br />
The URL can be used to link to this page
Your browser does not support the video tag.