Laserfiche WebLink
• Electronics and operational controls fully enclosed in a <br />lockable cabinet capable of housing up to 12 AH batter- <br />ies. <br />• Optional LED-10 Series Remote Annunciators operate <br />off serial two-wire EIA-485 interface. <br />• Optional contact-by-zone module and printer interface <br />for on- or off-line printing. <br />• 230 VAC, 50 Hz international version available. <br />REMOTE SITE UPLOAD/DOWNLOAD <br />The MS-5210UD may be downloaded or uploaded (requires <br />panel software revision #MS52103.0 or greater) without <br />compromising the system fire protection at the protected <br />premises. <br />• Download system programming. <br />• Upload key system information: <br />✓ Current system status, history + walk test files. <br />✓Zone, AC line, NAC1, 2, 3 and 4, resettable power <br />and battery voltages. <br />✓ System programming. <br />• Upload or download within one minute without affecting <br />normal fire panel functions. <br />• Multiple security techniques. <br />• Requires PK-5210UD programming kit, which works with <br />most Hayes-compatible modems (consult factory for list- <br />ing). <br />SPECIFICATIONS <br />Single PC board design using Surface Mount Technology <br />(SMT). Two modular telephone jacks for connection to <br />RJ31 X/Modules. <br />AC Power <br />• 120 VAC, 50/60 Hz, 2.3 amps. <br />• 230 VAC, 50 Hz, 1.2 amps ("E" suffix). <br />• Wire size: minimum 14 AWG with 600-volt insulation. <br />• Built-in brownout circuitry. <br />• Built-in voltmeter. <br />Communicator <br />• One line-active indicator for each of two phone lines. <br />• "Kiss-Off' signal LED. <br />• Dual "low telephone voltage detect" circuitry. <br />• Programmable event codes per each format. <br />• Up to 100 transmitted events/messages. <br />• Selectable/deselectable transmissions of 100 events. <br />Communication Formats <br />Express and Ademco Contact ID formats allow complete <br />transaction to be communicated in under five seconds. <br />• Ademco Contact ID. <br />• 20 PPS, 3+1 standard and expanded. <br />• 20 PPS, 4+1 standard and expanded. <br />• 20 PPS, 4+2 standard and expanded. <br />- 4+1 and 4+2 Ademco Express. <br />INITIATING DEVICE CIRCUITS (ZONES) <br />The MS-5210UD includes ten programmable Class B Initi- <br />ating Device Circuits (zones). Use the CAC-10F Class A <br />converter module to convert all Class B IDCs/NACs to <br />Class A. <br />Each zone may support two-wire smoke detectors. Pro- <br />gramming options include: <br />• Normally Open Contact devices (pull, heat). <br />• Four-wire smoke detectors. <br />Page 2 of 3— DF-51492 • 07/12/04 <br />• Waterflow (silenceable/non-silenceable) operation. <br />• Supervisory (standard/auto-reset) operation. <br />• Remote switch for Reset, Drill, Silence, Acknowledge. <br />• Critical and Noncritical Process Monitoring (standard/ <br />auto-reset). <br />All circuits are power-limited and fully supervised. They <br />allow up to 100 ohms of line resistance and allow for use of <br />12 to 18 AWG wire. <br />NOTIFICATION APPLIANCE CIRCUITS <br />Two Style Y(Class B) @ 3.0 amps each. Use the CAC- <br />10F Class A Converter Module to convert all Class B <br />NACs and IDCs to Class A. <br />Option module adds two Style Z(Class A) NACs @ 1.5 <br />amps each. <br />All circuits are fully power-limited and meet the new UL <br />power-limiting requirements effective May 1, 1995, using <br />fuseless technology. <br />AUXILIARY OUTPUTS <br />• Resettable four-wire smoke detector power @ 500 mA. <br />• Non-resettable power @ 500 mA. <br />• Two fully programmable Form-A!B relays. <br />• Option module adds two fully programmable Form-C <br />relays. <br />COMPATIBLE DEVICES, EIA-485 PORT <br />LED-701M: EIA-485 Interface Module. Provides MS- <br />5210UD with EIA-485 output, capable of supporting up to <br />32 compatible EIA-485 devices (listed below). <br />LED-10 Series: LED-type fire annunciators capable of <br />displaying Alarm (red) and Trouble (yellow) LEDs for all ten <br />Initiating Device Circuits (IDCs). NOTE: For Canadian <br />Supervisory Service, use LED-10LS2 only. <br />AFM-16AF: LED-type fire annunciator capable of pro- <br />viding up to 16 zones ofAlarm (red) annunciation and com- <br />mon system trouble LED. Mounts to 4-gang electrical box <br />ONLY. <br />LDM Series: Lamp Driver Module series for use with <br />custom graphic annunciators. <br />ACM-8RF: Remote Form-C relay module. Provides eight <br />mappable Form-C relays driven by EIA-485 for contact-by- <br />zone capability (two minimum required for contact-by-zone). <br />Each requires ABS-8RF for mounting. <br />NOTE: For more detailed information on Compatible EIA-485 <br />Devices for use with the MS-5210UD, please refer to the LED-10, <br />AFM/AFM-X, LDM or ACM-8RF data sheets, document numbers <br />DF-51500, DF-51465, DF-51384, and DF-51555 respectively. <br />CABINET SPECIFICATIONS <br />The cabinet is red with a dark blue overlay. Knockouts on <br />the top, sides, and back provide ease of wire entry. The <br />cabinet can be surface or semi-flush mounted and is com- <br />pact in design. <br />Dimensions: <br />Door: 17.11" high x 14.71" wide <br />(43.46 cm high x 37.36 cm wide). <br />Backbox: 16.90" high x 14.50" wide x 4.50" deep <br />(42.93 cm high x 36.83 cm wide x 11.43 cm <br />deep). <br />Trim Ring: Part # TR-4-R, 20.020" high x 17.620" wide <br />(50.85 cm high x 44.75 cm wide). <br />