My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1910 MERRILL CREEK PKY 2018-11-15
>
Address Records
>
MERRILL CREEK PKY
>
1910
>
1910 MERRILL CREEK PKY 2018-11-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2018 11:33:47 AM
Creation date
1/12/2017 2:00:20 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
1910
Notes
GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
107
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. <br />van accessible. Existing parking on the west side of the building can be reconfigured to provide <br />required accessible parking with no net loss of spaces. <br />Fire Department <br />1. Fire Alarm Svstem - An approved automatic fire detection system shall be provided as <br />required by City Ordinance No. 3021-07, Chapter 16.76, of the Everett Municipal Code. <br />Plans for such system shall be submitted to the Fire Code Official for review and approval prior <br />to installation. Submittal shall include cut sheets of all equipment intended for use. Appropriate <br />trip tests, witnessed by a Fire Deparfinent Inspector, shall be performed, along with a certificate <br />of completion, prior to final acceptance of the system. <br />Fire alarm systems shall be installed according to NFPA Chapter 72. Instatlation of fire alarm <br />components, including basic wiring, may not commence before plans are approved by <br />the Fire Departmenfi Plan Reviewer. Fire alarm drawings must be professionally rendered, in <br />sufficient d�tail, and must be internally consistent. Riser diagrams must match instaflation plans <br />and load calculations. Components must be listed and approved for use together. Changes to <br />plans must include new drawings and calculations and must be approved by the Fire <br />Department Plan Reviewer prior fo installation. Fire alarm installation is subject to field <br />inspection by a Fire Department Inspector. An appraved set of plans and the Eng�neering & <br />Public Services Department electr�cal permit must be present for any installaiion inspection. <br />Fire alarm systems shall be insfalled under permit of the City of Everett Engineering & Public <br />Services Department. Electrical inspections and approval are required prior to calling for <br />acceptance tests. Call (425) 257-8810 for permit information. <br />The absence of working phone lines for the alarm system will be cause for postponing <br />Fire Depariment inspection and testing and shall result in denial of occupancy. <br />A copy of NFPA 72 Record of Completion form must be filled out prior to final occupancy (NFPA <br />72, 2d07 Edition, page 72-33). <br />Call for design requirements per Authority Having Jurisdiciion. <br />Automatic smoke detection is required. <br />Systems within the building must be extended in new additions per the Fire Marshal's Office. <br />Fire Suppression (Sprinkler} System - An approved aufomatic suppression system shall be <br />provided as required by City Ordinance No. 3021-07, Chapter 16.76, of the E�ereit Municipal <br />Code. The system must inciude a mechanical water gong bell. <br />Plans for any such system shafl be submitfed to the Engineering & Public Services Department <br />for examination and approval. Such plans shall include plans for the underground mains that <br />wi[I supply fhe sprinkler system. <br />The type of sprinkler to be installed will be determined by the Building Official. It may be an <br />NFPA 13, NFPA 13R, or NFPA 13D system depending upon several factors. Sprinkler <br />2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.