Laserfiche WebLink
, <br /> 7. All footings shall rest on undisturbed soil not less than 18" below the finished grade. <br /> Show all footing sizes on plans. <br /> "✓8. Provide details for all post/beam, post/footing connections. Specify all connectors. <br /> 9. Provide minimum 36" landing not more than 7-3/4" below the finished floor at the new <br /> Entry door. <br /> 10. Provide revised site plan with all items from City of Everett Residential Submittal <br /> Checklist shown on the site plan. Revise height calculations to be consistent with the <br /> Height calculation handout. (3 copies, no larger than 11"x 17", minimum <br /> scale 1" = 20') <br /> 11. Specify moisture barrier on exterior walis and siding material. <br /> Please prepare a response letter showing where each item in this <br /> correction letter is addressed on the plan set. <br /> Upon resubmittal of the drawings, your application will be given prioriry and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely,� <br /> ������.� ---� <br /> ; <br /> Jeff Heilman <br /> Development Technician <br /> 425-257-8976 <br /> Emai!: iheilman�aci.everet�.v��a.�.�s <br /> ��i�;,�..,� <br /> S:\1Common\Clerical\]Heilman\C1507-001(10115 23rd Ave W).doc <br />