Laserfiche WebLink
� 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and >3 story R2 and R3 <br /> � 2012 Washin ton State Ener Code Com liance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Ma 2015 <br /> Project Info Project Address: NATIONAL GENERAL INSURANCE Date 2/23/2016 <br /> 332 SW EVERETT MALL WAY For Building Dept. Use <br /> EVERETT,WA 98204 ����^� r �� <br /> , Applicant Name: RANDY HINTON / �� <br /> Applicant Address: 20201 CEDAR VALLEY RD,STE.120,LYNNWOOD <br /> Applicant Phone: 425-774-3829 <br /> Project Description ❑ New Building ❑ Building Addition Q System Upgrade � No System Changes <br /> Briefly describe mechanical systems in <br /> the text box provided PROJECT CONSISTS OF REPLACING(2) EXISTING PACKAGED GAS FIRED ROOFTOP UNITS OF SAME <br /> ❑Total Bldg Performance SIZE AND TYPE AND ADDING(4)VAV BOXES WITH ELECTRIC HEAT ON THE FLOORS BELOW. <br /> Total Bldg Performance compliance <br /> includes all mandatory provisions per <br /> C401.2 Option 2. Only MECH-SUM <br /> and MECH-CHK forms required. <br /> Mechanical Systems Suinmary <br /> Air <br /> Compliance Heating Fan Flow Economizer Ventilation <br /> Equip ID Type of System(Note 1) Space(s)Served Path and Cooling Controls (Note 2) (Note 3) Energy Recovery <br /> AHU-1 PACKAGED GAS/AC RTU 4TH FLOOR Complex multi Heating and Variable air Yes Minimum per Not Applicable <br /> zone system cooling volume(VAV) IMC <br /> AHU-2 PACKAGED GAS/AC RTU 1ST-3RD FLOOR Complex multi Heating and Variable air Yes Minimum per Not Applicable <br /> zone system cooling volume(VAV) IMC <br /> VAV FB- Simple single Constant No cooling, Minimum per <br /> 39 VAV WITH ELEC HEAT 1ST FLOOR zone system Heating only �olume(CV) NA IMC Not Applicable <br /> VAV FB- Simple single Constant No cooling, Minimum per <br /> 40 VAV WITH ELEC HEAT 1ST FLOOR zone system Heating only volume(CV) NA IMC Not Applicable <br /> VAV FB- VAV WITH ELEC HEAT 1ST FLOOR Simple single Heating only Constant No cooling, Minimum per Not Applicable <br /> 41 zone system volume(CV) NA IMC <br /> VAV FB- Simple single Constant No cooling, Minimum per <br /> 42 VAV WITH ELEC HEAT 3RD FLOOR zone system Heating only volume(CV) NA IMC Not Applicable <br /> Note 1-Provide basic description of system type, for example: unitary rooftop air handler,built-up central air handler, single-packaged,split system or packaged <br /> terminal air conditioner or heat pump;unit heater, warm-air furnace,electric resistance heater, 4-pipe fan coil, VRF system, energy recovery air handler, <br /> make-up air system, ground or water-source heat pump, etc. <br /> Note 2-If taking an exception to air economizer, select exception taken from drop down menu and complete MECH-ECONO form. Summary definitions of each <br /> exception are listed in MECH-ECONO. <br /> Note 3-If ventilation"Not applicable"is selected,provide explanation in Project Description box above. <br /> ❑ Hydronic chilled water � Water-loop heat pump 0 No hydronic systems <br /> HVAC Hydronic Systems <br /> ❑ Hydronic heating � Geothermal <br /> Equipment Type(s) <br /> ❑ Hot water heating tank(s) ❑Instantaneous ❑' No service water systems <br /> . Service Water Heating �Heat exchange from space heat boiler or <br /> ❑ Dedicated boiler <br /> Systems central hot water/steam <br /> Distribution Type(s) <br /> ❑Circulation System ❑ On-demand <br />