Laserfiche WebLink
� 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and >3 story R2 and R3 <br /> • � . � . <br /> � 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised May 2015 <br /> Project Info ProjectAddress: NATIONAL GENERAL INSURANCE Date 2/23/2016 <br /> 332 SW EVERETT MALL WAY For Building Dept. Use <br /> EVERETT,WA 98204 <br /> � Applicant Name: RANDY HINTON <br /> Applicant Address: 20201 CEDAR VALLEY RD,STE. 120, LY <br /> Applicant Phone: 425-774-3829 <br /> Fan S stem ID AHU-1 A separate MECH-FANSYS form must be completed for every HVAC system <br /> y that exceeds the 5hp threshold. <br /> System Supply Fan VAv Constant Volume(CV), Variable Air Volume(VAV),or Hospital/Lab CV system <br /> S eed Control that qualifies for VAV budget per C403.2.10.1,Exception 1 <br /> Compliance is based upon either the fan motor nameplate horse power(Option <br /> Compliance Option Nameplate HP 1)or the fan brake horsepower(Option 2)_ The bhp calculation provides <br /> adjustments for special equipment per Table C403.2.13.1(2). <br /> Provide maximum design supply airflow rate(CFM)of all supply fans serving <br /> Fan S stem Su 1 the conditioned space in Fan Equipment Schedule be/ow. Fan System CFM <br /> y pp y 7,500 Total is the supply airflow of the central air handler at peak design conditions. <br /> CFM Total Additional volumetric air flow provided at zone fan terminals, booster fans, or <br /> through induction is not included in the supp/y CFM total.However, the fan <br /> power of this equipment is included in the HP and BHP ca/cu/ations. <br /> Fan E ui ment Schedule <br /> Total CFM Total Nameplate Total BHP <br /> Fan ID and Location Fan Type Quantity of Fan Type (Note 1) HP(Note 2) (Note 3) <br /> AHU-1 Supply 1 7,500 7.5 <br /> AHU-1 Return 1 6,800 3 <br /> Note 1- Total CFM is the maximum CFM of the listed fan(s) when Total Proposed: 10.5 <br /> operating at peak design operating conditions. <br /> Note 2- Total namplate hp of the listed fan(s). Total Allowance: 11.3 #VALUE! <br /> Note 3- Total brake horsepower(bhp)of the listed fan(s)at peak <br /> design operating conditions. Not required <br /> it Nameplate HP compliance option chosen. Compliance Message: COMPLIES <br /> Brake Horsepower Allowance Adjustments <br /> Calculated <br /> Assigned Pressure Adjustment, <br /> CFM thorough this Pressure Drop, <br /> Device Type Description and Location device(CFMD) Drop, PD in w.c. pD in w.c. A in bhp <br /> (Note 5) (Note 6) (Note 7) <br /> Note 4-Bhp allowance for energy recovery devices and run around coil loops inc/udes both air Total Adjustment(bhp): <br /> streams,so the CFMD is the sum of the supp/y CFM and exhaust CFM if both go through <br /> the device. <br /> Note 5-Assigned pressure drop(PD)adjustment per Table C403.2.10.1(2). <br /> Note 6-Pressure drop(PD)adjustment shall be calculated per the applicable method <br /> defined in Table C403.2.10.1(2)based on specific system conditions. <br /> Note 7-A =PD`CFMD/4131 where A is the allowed system brake horse power <br /> � adjustment, PD is pressure drop al/owance, and CFMD is the cfm through the device. <br />