My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
332 SW EVERETT MALL WAY NATIONAL GENERAL INSURANCE 2017-04-06
>
Address Records
>
SW EVERETT MALL WAY
>
332
>
NATIONAL GENERAL INSURANCE
>
332 SW EVERETT MALL WAY NATIONAL GENERAL INSURANCE 2017-04-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2017 2:26:48 PM
Creation date
1/17/2017 2:29:27 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
332
Tenant Name
NATIONAL GENERAL INSURANCE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
114
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 <br /> � � . � . <br /> . <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised May 2015 <br /> . <br /> Project Info ProjectAddress: NATIONAL GENERAL INSURANCE Date 2/23/2016 <br /> 332 SW EVERETT MALL WAY For Building Dept. Use <br /> EVERETT,WA 98204 <br /> � Applicant Name: RANDY HINTON <br /> Applicant Address: 20201 CEDAR VALLEY RD,STE. 120,LY <br /> Applicant Phone: 425-774-3829 <br /> Fan S stem ID AH U-2 A separate MECH-FANSYS form must be comp/eted for every HVAC system <br /> y that exceeds the 5hp threshold. <br /> System Supply Fan VAV Constant Volume(CV), Variable Air Volume(VAV),or Hospital/Lab CV system <br /> S eed Control that qualifies for VAV budget per C403.2.10.1, Exception 1 <br /> Compliance is based upon either the fan motor nameplate horse power(Option <br /> Compliance Option Nameplate HP 1)or the fan brake horsepower(Option 2). The bhp calculation provides <br /> adjustments for special equipment per Table C403.2.13.1(2). <br /> Provide maximum design supply airflow rate(CFM)of all supply fans serving <br /> Fan S stem Su 1 the conditioned space in Fan Equipment Schedule be/ow.Fan System CFM <br /> Y PP Y Total is the supp/y airtlow of the central air handler at peak design conditions. <br /> 25,000 Additional volumetric air flow provided at zone fan terminals, booster fans,or <br /> CFM Total <br /> through induction is not included in the supp/y CFM total. However, the fan <br /> power of this equipment is included in the HP and BHP calculations. <br /> Fan E ui ment Schedule <br /> Total CFM Total Nameplate Total BHP <br /> Fan ID and Location Fan Type Quantity of Fan Type (Note 1) HP(Note 2) (Note 3) <br /> AHU-2 Supply 1 25,000 30 <br /> AHU-2 Return 1 21,000 7.5 <br /> Note 1 - Total CFM is the maximum CFM of the listed fan(s)when Total Proposed: 37.5 <br /> operating at peak design ope�ating conditions. <br /> Note 2- Total namplate hp of the listed fan(s). Total Allowance: 37.5 #VALUE! <br /> Note 3- Total brake horsepower(bhp)of the listed fan(s)at peak <br /> design operating conditions. Not required <br /> if Nameplate HP compliance option chosen. Compliance Message: COMPLIES <br /> Brake Horsepower Allowance Adjustments <br /> Calculated <br /> Assigned Pressure Adjustment, <br /> Device Type Description and Location CFM thorough this Drop, PD in w.c. Pressure Drop, A in bhp <br /> device(CFMD) PD in w.c. <br /> (Note 5) (Note 6) (Note 7) <br /> Note 4-Bhp allowance for energy recovery devices and run around coil loops includes both air Total Adjustment(bhp): <br /> streams,so the CFMD is the sum of the supply CFM and exhaust CFM if both go through <br /> the device. <br /> Note 5-Assigned pressure drop(PD)adjustment per Table C403.2.10.1(2). <br /> Note 6-Pressure drop(PD)adjustment shall be calcu/ated per the app/icab/e method <br /> defined in Table C403.2.10.1(2)based on specific system conditions. <br /> Note 7-A =PD*CFMD/4131 where A is the allowed system brake horse power <br /> � adjustment, PD is pressure drop allowance,and CFMD is the cfm through the device. <br />
The URL can be used to link to this page
Your browser does not support the video tag.