Laserfiche WebLink
REQUIRED <br />INSPECTION <br />APPROVED <br />IMPORTANT: DO NOT place checks In the two left columns. <br />C3 p E) Exposed foam Insulation shall comply as follows (S. 502.1.4.7): <br />❑ Protected with metal or plastic flashing, or other suitable material that extends below grade. <br />❑ Insulation is approved for sub -grade, exterior use and properly Installed. <br />C3 ®Alrilow between .rash air ports and the whole -house fan ensured by undercut doors/gdlls(VIAQ,S. 302.4.4) <br />i D ©LoosefIII Insulation OK If (S.502.1.4.5): <br />❑ maximum ceiling slope not > 3 In 12 <br />❑ x 300 of clear distance from top of bottom chord to underside of roof sheathing at the roof ridge. <br />p p 016 mil black polyethylene ground cover, shall be lapped 12' at Jolnls and extend to foundation wall <br />p er Clearances shall meet listed minimums between Insulation and (S.502.1.4.3): <br />❑ chimney ❑Non -IC rated recessed lights: 1/2'to combustables, 3'to Insulation. <br />C3 gqAttic hatch shall be Insulated to required ceiling R-value and is weatherstripped (S.502.1.y.4) <br />p Attic access shall have wood dam or equivalent to retain loose fill Insulation In attic(S. 502.1.4.4) <br />p WAII exterior doors (except 20 minute doors) shall be weatherstripped (S. 502.4.3). <br />C3 r Service hot 6 cold water piping in unconditioned spaces shall be Insulated to R-3(S. 503.11) <br />O Service recirculation hot water piping In unconditioned spaces shall be Insulated to Table 5-12 levels. <br />p @Heat pump thermostat shall have progamable capability (S. 503.8.3.5) <br />E3 a hermoslat provided for each HVAC system with range of 55.75' F.(heating) (S.503.8.1.1). <br />1-3Readlly accessible, automatic or Manual means provided to restrict or shut-off Heating Input to each <br />zone or floor during periods not requiring heat (S. 503.8 3.1). <br />p mcontrols for backup heal prohibit simillaneous operation of the primary system (S. 503.2.2(3)). <br />E3 p chanlcal ventilation system shall have proper timers, and/or switches (VIAO, S. 302.3). <br />C3 p odechanical ventilation ducts shall have R-4 insulation In unconcfitinned spaces (VIAO, S. 302.5) <br />p E3 OvIechanIcal ventilation supply ducts in r.Dndltloned spaces shall have R-4 insulation (VIAQ, 302.5) <br />p C3 @Dupply ducts shall have volume dampers, or the equivalent, to balance system (S. 503.6). <br />p E3 upply and return air ducts shall have sealed duct binis in unconditioned spaces (S. 503.10.2). <br />p p r VAC plenums, supply, and return air ducts shall have R-8 insulation (Table 5-11, All options) <br />0 T leclrlc water heaters) shall have (S. 504.2.1, 504.3, 504.4) : <br />❑ separate power . shut-off ❑ 1987 NAECA Lable on tank <br />❑ noncompressible R10 pad (unheated spaces only) ❑ Temperature settings 120 F. <br />0 �howers and lavatories shall limit flow to s 3.0 gallonsiminute (S. 504.8.1). <br />E3 O wlmming pools(S. 504.5) shall have: <br />❑ readily accessible OWOFF switch (pump, heater) ❑Pool cover ❑Piping Insulated to S. 503.11 <br />p p @D1111 fireplaces (VIAO, S. 402.3) shall have: <br />❑ 6 square Inch combustion air supplyducl w/ accessible damper directly connected to the fire box <br />❑ Tight fitting glass or metal doors. ❑ Tight fitting flue damper <br />O O s Solid fuel burning a)pllance(s) (VIAQ, S. 402.2) shall have: <br />❑Tight filling glass or metal doors <br />❑Outside combustion air source directly connected to the lire box <br />❑ Exception: Non -direct, 4' diameter, dampered, combustion air source: allowed only for (1) new stove <br />Installations In existing homes where obstructionsprecludes direct combustion air, or (2) Central <br />healing systems located In unheated spaces. <br />n p 0 Three month, etched track radon monitor, printed Instructions, and Information sheets shall be supplied <br />to the single family dwelling or first floor uni s of multi -family dwellings by the general cAnlractor (VIAQ,S. <br />502.2.1), <br />wBEc Final phase requirements: <br />Inspected by. Dafs <br />Page 6 of 6 <br />