Laserfiche WebLink
5. Provide min 50 cfm fan in both new bathrooms. <br />6. Specify min 36" height on interior and exterior guardrails. Show <br />guardrails on plans. <br />7. Provide detail of bay windows. Show cantilever and roof structures. <br />Show insulation. <br />8. Show all valleys and ridges on roof framing plan. <br />9. Provide ventilation calcWations for the attic. Show vents on plans <br />and/or elevations. <br />10. Provide min 22"x30" attic access with min 30" clear headroom over <br />opening. <br />11. Detail intermediate supports in crawl space. Show post/beam <br />connection and post/footing connection capable of resisting uplift <br />and lateral displacement. <br />12. Provide engineering for two-story walls with full height studs. <br />13. Provide bearing for point loads on stairs. <br />14. Provide min 1" clear air space over insulation in attic, specify on <br />plans. <br />15. Provide solid blocking at ea6h rafter. <br />16. Insulation baffle shall extend min 6' vertically above batts and 12" <br />vertically above loose fill insulation. <br />17. Provide fire blocking at concealed spices of stud walls and partitions <br />including furred spaces at the ceiling and floor levels and at 10'0" <br />intervals both horizontal and vertical. <br />18. Specify interior wall and ceiling material. <br />19. Specify decking material. <br />20. Specify size and spacing of lag bolts at deck ledger. <br />21. Verify existing exterior stud walls are not less than 20 ® 16" o.c. <br />22. All footings shall rest on undisturbed soil not less than 18" below <br />the finished grade. <br />23. Provide cross section of covered porch. Show how trusses are <br />connected to house. <br />DED1'PLNCAMSTWHE1LMAN117 W BEECH ST IILLINGSLEY <br />