Laserfiche WebLink
Cavital Arclutects Incor� __ated <br /> ` 2813 Rockefeller Ave.Everett,WA 98201• ph:425.317.8017 • fax:425.317.8489 <br /> March26.2014 (.e�e�J 91a/ ►�r w�� J�✓��S f��'� Svrr�:. c�G`K • <br /> U <br /> City o(Everett <br /> Planning Department <br /> 3200 Cedar St. <br /> Everett,WA 98201 <br /> Attention:Meg Haley, Plans Ezaminer <br /> RE:Permit Number. B1402-044, IGOl Broadway Uaycare Charge of Use/Remodel and AdciGon <br /> Dear Meg, <br /> This is in response to your rewew dated March 10,2014,sent vla emad ��1ard�25, 2014 in regard to atans submitted fnr a <br /> tenant improvement at[he address indica[ed above. <br /> 6enerel: <br /> ]. To identi/y what is 6eing proposed as new work on this permit,please revise the draw�ngs os Jollows: <br /> a. New wark should be indica(eAwith dark lines. Existing work should be indicoted as light lines,and <br /> demolition work should be indimted witb doshed lines. <br /> Sheets A-2.0 and A-2.],labeled"Existin�Floor Plans"and"Demolition Floor Plans",respectively,were <br /> induded in the original permit subminal.7hese plans currently show the existing conditions,as wrll as <br /> walls,windows,doors,etc.,to�e removed during demolition. <br /> 7he layer for the hatch indiwting new construction(sheet A-2.3)was accidentally tumed off durin� <br /> printing.This layer should be visible now with the revised floor plan.All new walls are shaded. <br /> b. The drawings shouldbe denr enough tha[the smpe oJ worl:and fhe new work ond dernolition cauld <br /> be undentood ond bui;f by someone other than the submitter. <br /> Noted. <br /> c. Portions oJthe building hove been previousty al[ered wifhout permits. The Jollowing cormct'ions,listed <br /> by cade tapic,should be show�i as new work on the drawings(drawn with dork lines on the plons, <br /> detailed in sertion and elevation to meet current code). <br /> 7he U�ans s�bmitted are based upon existing conditions.Our scope of work is based upon exisling <br /> condi[ion,. <br /> d. z should be enough inJormotinn on the pia,vs thot someone other ihon the orchi(ect or the owoer <br /> c_.,build i[without seeking odditional dariJicution on newand existing wu�k. <br /> Noted.Contrectors bidding on project have well understood existing condiCans and proposed scope. <br /> Occupancv: <br /> 1. Pleose show the occupancy type(tlassiJicotionj ond age of children,per IBCToble 1004.7.2. For the purpose o/ <br /> the certiJicote oJoccupancy,pleose indude the toml occupnnt load of the building summvrized in o code <br /> onalysis section on the caversheet. <br /> Thr.occupan[load table has been updated with additional information on the cover sheet(�-1.0�,and is based <br /> . upon maximum state allowances.State licensing regulations suVersede BC caiculations. <br /> � <br /> 1 �.��age <br /> �'� <br /> e�� <br />