My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3128 BROADWAY WHOLE SITE DOCUMENTS 2016-01-01 MF Import
>
Address Records
>
BROADWAY
>
3128
>
WHOLE SITE DOCUMENTS
>
3128 BROADWAY WHOLE SITE DOCUMENTS 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2017 4:26:15 AM
Creation date
1/24/2017 4:26:05 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3128
Tenant Name
WHOLE SITE DOCUMENTS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' � � � <br /> construc[ion rated separa[ions and tested assemblies reyuired at setbacks from actual <br /> property lines,or separating units at imaginary property lines. Sections should be shown <br /> at he porch roof at the Unit 1 and 2 exterior walls, and at all roof elevation height <br /> char�ges, typical. Comply with Emergency Rule R302.1 dated March 17,2014 <br /> �a. The section through the common hvo-hour fire resistant assembly of unit A <br /> should be targeted on the plan drawings. Another section should be shown for <br /> the framing running parallel to Unit B. R302.2(2) <br /> J b. 7he shared [wo hour rated fire barrier separating one unit from the other cannot <br /> be penetrated at the porch entry. A section through the porch to show the <br /> common rivo hour fire•resistant-reted wall assembly should be shown on the <br /> �� drawings. <br /> "c. The roof deck sheathing should be shown as either non-combustible, or fire <br /> retardant treated wood, or protected by 5/f� inch Type X gypsum board for a <br /> distance of four feet on either side of the common hvo hour reted wall assembly, <br /> or parapet should be shown. R302.2.2 (2) <br /> � d. The acarate tested assembly should be shown on the drawings for the actual <br /> � requirements for the wall fire-resistance reting of a shared two hour fire resistant <br /> � wall. Table R302.1(1) <br /> � e. Eaves of one townhouse cannot be shown to project over the other townhouse <br /> n the drawings. Table R302.1(1) <br /> f. Nater from one townho�se cannot drein directty onto another townhouse. The <br /> gutter system should be shown on the drawings and can project over the o[her <br /> townhouse. EMC 16.01.010 K ' <br /> ✓��g1Construction near property lines (real or imaginary) should be drawn in section, <br /> `j targeted on the plans, and shown with fire resistance retings required a[ wall <br /> sections and projections. Table R302.1(1) <br /> �h. Openings in walls are prohibited within three feet of a property line (real or <br /> imaginary). Table R302.1(1) <br /> �i. Projections within two feet of the property line are prohibited. Table R302.1(1) <br /> J j. A section through the stair that is located within 1 foot of the property line <br /> should be shown on the plans. <br /> k. The cantilever d�tail shone on sheet 6 should be targeted on the plans. <br /> I. Draftstops should be shown on lhe drawings in the fioor ceiling assembly <br /> between units. R302.12 <br /> 1. Fireblocking should be shown on the drawings between the top story and the <br /> roof space. Show fireblocking on exterior framing detail. R307..11 <br /> 3. 7he exterior door for Unif C should show a section through the landing on the drawings <br /> on both sides of the door. The exterior drop should not exceed 7 3/n". The grede <br /> elevation should be shown on the plans, with either a ramp or stair if it is not level with <br /> the landing. R31].3.1 <br /> 4. 1 3/8"solid core wood door with self closer between garage and living space should be <br /> shown on the drawings. <br /> 5. Tempered glazing should be shown at ail locations required per IRC 308.4. <br /> � The attachment of the balcony should be shov+n in detail on the drawings to show <br /> positive anchoring to resist lateral and vertical forces. R311.5.1 <br /> , 3 �/ <br /> ,_ - <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.