' � � � <br /> construc[ion rated separa[ions and tested assemblies reyuired at setbacks from actual <br /> property lines,or separating units at imaginary property lines. Sections should be shown <br /> at he porch roof at the Unit 1 and 2 exterior walls, and at all roof elevation height <br /> char�ges, typical. Comply with Emergency Rule R302.1 dated March 17,2014 <br /> �a. The section through the common hvo-hour fire resistant assembly of unit A <br /> should be targeted on the plan drawings. Another section should be shown for <br /> the framing running parallel to Unit B. R302.2(2) <br /> J b. 7he shared [wo hour rated fire barrier separating one unit from the other cannot <br /> be penetrated at the porch entry. A section through the porch to show the <br /> common rivo hour fire•resistant-reted wall assembly should be shown on the <br /> �� drawings. <br /> "c. The roof deck sheathing should be shown as either non-combustible, or fire <br /> retardant treated wood, or protected by 5/f� inch Type X gypsum board for a <br /> distance of four feet on either side of the common hvo hour reted wall assembly, <br /> or parapet should be shown. R302.2.2 (2) <br /> � d. The acarate tested assembly should be shown on the drawings for the actual <br /> � requirements for the wall fire-resistance reting of a shared two hour fire resistant <br /> � wall. Table R302.1(1) <br /> � e. Eaves of one townhouse cannot be shown to project over the other townhouse <br /> n the drawings. Table R302.1(1) <br /> f. Nater from one townho�se cannot drein directty onto another townhouse. The <br /> gutter system should be shown on the drawings and can project over the o[her <br /> townhouse. EMC 16.01.010 K ' <br /> ✓��g1Construction near property lines (real or imaginary) should be drawn in section, <br /> `j targeted on the plans, and shown with fire resistance retings required a[ wall <br /> sections and projections. Table R302.1(1) <br /> �h. Openings in walls are prohibited within three feet of a property line (real or <br /> imaginary). Table R302.1(1) <br /> �i. Projections within two feet of the property line are prohibited. Table R302.1(1) <br /> J j. A section through the stair that is located within 1 foot of the property line <br /> should be shown on the plans. <br /> k. The cantilever d�tail shone on sheet 6 should be targeted on the plans. <br /> I. Draftstops should be shown on lhe drawings in the fioor ceiling assembly <br /> between units. R302.12 <br /> 1. Fireblocking should be shown on the drawings between the top story and the <br /> roof space. Show fireblocking on exterior framing detail. R307..11 <br /> 3. 7he exterior door for Unif C should show a section through the landing on the drawings <br /> on both sides of the door. The exterior drop should not exceed 7 3/n". The grede <br /> elevation should be shown on the plans, with either a ramp or stair if it is not level with <br /> the landing. R31].3.1 <br /> 4. 1 3/8"solid core wood door with self closer between garage and living space should be <br /> shown on the drawings. <br /> 5. Tempered glazing should be shown at ail locations required per IRC 308.4. <br /> � The attachment of the balcony should be shov+n in detail on the drawings to show <br /> positive anchoring to resist lateral and vertical forces. R311.5.1 <br /> , 3 �/ <br /> ,_ - <br /> � <br />