My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5505 BROADWAY RECORDS STORAGE ONLY 2016-01-01 MF Import
>
Address Records
>
BROADWAY
>
5505
>
RECORDS STORAGE ONLY
>
5505 BROADWAY RECORDS STORAGE ONLY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2018 7:22:55 AM
Creation date
1/24/2017 9:04:07 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
5505
Tenant Name
RECORDS STORAGE ONLY
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOUO(I81t005 <br /> Sprcad footing foundations may bc used for foundation support of thc planned singlc family <br /> residences when foundcd on medium dense, documented swctural fill. An allowablc <br /> foundation bearing capacity of 2000 pounds per squarc foot may be uscd for design of thc <br /> spread footings. A shon term incrcase of one-third may be used for wind,snow, or seismic <br /> loads. Steps in thc foundation grade arc acceptablc provided that none of the foundations are set <br /> to bcar adjacent to Uic slep. A ]I1:I V load line extending down from lhc edge of the foundation <br /> must not daylight a cut slope. Anticipatcd settlemcnt of the foundation when properly set to bcar <br /> on an approved bearing stratum will be Icss than 1 inch. We recommend that Dattemiann <br /> Gcotcchnic:il Consulting, pllc pccform a foundation soil bcaring cvaluation prior to placing <br /> foundation concrctc. <br /> Floor Support <br /> Slab-on-grade concrctc iloors should be cast atop a p�pamd subgrs:le. The subgrade soils <br /> should bc compacted to a minimum of 90 percent oC Ihe modified Proctor maximum dry density <br /> or be firm, non-yielding native sediments. 17�e floor slab should be cast atap a capillary break <br /> consisting of a minimum of 4 inchcs of pea gravcl or clean crushed rock with Icss ehan 5 percent <br /> fines (materia] passing the No.200 sieve). The capillary brealc will reduce the potential for <br /> moisturc Gom wicl:ing through thc floor slab. A plastic shccUng vapor barricr should also be <br /> placed atop U�e capillary 6rcak materi:il. All conerele placement should follow the guidclines <br /> set forih by the American Concrete Institute (ACI). <br /> Drainagc Considcrations <br /> A perimcter foundation drain should bc eslablished to prolect the foundation/mwlspace from <br /> ground waler inwsion. The Icvcl oCthe foundation drain sUould be sct at, or sliglrily bclow, thc <br /> base of the footing elevation. The drain should consist of 4 inch diametcr, rigid, perforated, <br /> PVC drain pipc and should be set to nllow for gravity discharge. '1'he drain pipc should hc <br /> surrounded by a minimum nf 6 inches of pea gnvcl or washed dnin rock.. Roof drains should <br /> not tic into U�e fooling drain but should be c;ollected in a scparate, Uglilline drain. The drains <br /> should be routed to discharge on a rockcd splash pad at the east side of the property wherc <br /> curnnt runo(1'from the site discharges. Tlie rocked splash pad should be a minimum of 4 fect <br /> widc by 6 Icct long by 1 '/: tcct tl�ick. The top of thc pad should hc fltLsh wiili thc ground <br /> surf:�cc and should hc constnictcd usin�, G to 12 inch diamc�cr crushcd mck <br /> Conclusion <br /> I�icld conswction monitoring and observation scrvices should be considcrcd an extension of <br /> this initial geotechnical cvaluation, and are essential to Gre deterniination of compli:uice with thc <br /> projcct drawings and spccitic:ations. Such activitics would incl�dc sitc cicaring a�id grading, <br /> subsurface drainagc, foundntion bearing soil cvaluations, fill placement and compaction. <br /> Our findings and rccommendations provided in this report wcrc pr�pated in accordancc will� <br /> generally acceptcd principles of enginecring geology and gcotcchnica] enginecring as practiced <br /> in thc Puget Sound arca at thc lime this rcport was submitted. Wc maY.c no other w:uranty, <br /> cilhcr cxpresscd or implied. <br /> BGC, pllc 14267 209�'Avenue NE, Woodinville, WA 98077 (425) 273-5062 <br />
The URL can be used to link to this page
Your browser does not support the video tag.