My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8223 BROADWAY 2016-01-01 MF Import
>
Address Records
>
BROADWAY
>
8223
>
8223 BROADWAY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/26/2017 11:31:30 AM
Creation date
1/24/2017 10:43:02 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
8223
Notes
PREVIOUS 1932 MOUNTAIN VIEW LN
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
182
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
be professionally rendered, in sufficient delail, and rtwst be intemally consistent. <br />Riser diagrams musi match installation plans and load calculations. . <br />Componen(s must be listed and approved for use together. Changes io plans <br />must include new drawings and calculations and must be approved by the Fire <br />Deparlment Plan Reviewer prior lo insiallation. Fire alarm installalion is subjecl <br />to field inspection by a Fire Department Insp�clor. An approved set of plans and <br />the Engineering 3 Public Services Department electrical permit must be present <br />for any installation inspection. Fire a�arm syslems shall be installed under permit <br />of the City of Everett Engineering & Public Services Department. Electrical <br />inspections and approval are required prior to calling for acceptance tests. Call <br />(425) 257-8810 for pertnit information. The absence of working phone lines <br />for the alarm system will be cause for postponing Fire Department <br />inspectlon and testing and shall result in denial of occupancy. <br />13. Commercial Cookin4 Operations (if aaolicabiel - A ventilating hood and duct <br />system with an approved automatic fire-exiinguishing system shall be provided in <br />accordance with the Mechanical Code for commercial-type food heat-processing <br />equipment that produces grease-laden vapors. <br />14. Fire Suopression (Sprinklerl Svstem - An approved automatic suppression <br />system shall be provided as required by City Ordinance No. 3021-07, Chapter <br />16.76, of lhe Evereti Municipal Code. The system must include a mechanical <br />water gong bell. Plans for any such system shall be submitled to tfie <br />Engineering & Public Services Depariment for examination and approval. Such <br />plans shall include plans for the underground mains that will supply the sprinkler <br />system. The lype of sprinkler to be installed will be determined by lhe Building <br />Official. It may be an NFPA 13, NFPA 13R, or NFPA 13D system depending <br />upon several factors. Sprinkler installation shall not begin without an <br />approved and stamped set of plans from the Engineering & Public Services <br />Department. The Fire Depariment will also review the plans and shall field <br />inspect the installation based only on approved plans that must be on site. <br />Changes to plans must be approved by bolh the Engineering & Public Services <br />an� Fire Departments. Aboveground sprinkler piping shall be hydrostatically <br />tesled as established in NFPA Standard 13. Underground piping shall be <br />hydrostatically tested and flushed as established in NFf'A Slandard 24 for <br />private fire mains. lE3elow-qround pipinq must be installed bv Washinqton <br />For further information, contact the State Fire Marshal's Offfce it (360) 570- <br />3134 or contact the Everett Fire Department at (425) 257-8123.) All such <br />iests shall be witnessed by a Fire Department Inspector. Call (425) 257-8124 to <br />make an appointment for inspection. Contraciors' materials and !ast certificates <br />shall be submitied to lhe [vereti Fire Depariment prior to issuar�ce of any <br />Certificates o( Occupancy. Call (425) 257-8123 for more information. <br />
The URL can be used to link to this page
Your browser does not support the video tag.