My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
909 N BROADWAY 2018-01-01 MF Import
>
Address Records
>
N BROADWAY
>
909
>
909 N BROADWAY 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2018 2:58:44 PM
Creation date
1/24/2017 12:58:48 PM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
909
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�` <br />Pacr a <br />Primary accessible entrance at existing door Cla is Iabeied on A2.0. Please see <br />A1.1 for push pull side dimensions. <br />2. Wifhin the property line, ramp, sidewalk, and stair widths should be dimensioned on the <br />drawings to be a minimum of 44 inches, per I8C section 1101.2.2, when they are part of <br />the accessible route, per IBC section 1104.2. <br />All remps and stairs have been dimensioned and are larger than 44 inches wide <br />3. New accessible parking spaces should be dirnensioned on thP drawings per the <br />requirements of IBC Chapter 11, to include the required van space, per IBC section <br />1106.5. <br />a. Access aisles should be dimensioned per ICC/A�JSI A117.1-2009 sedion 502.4. <br />b. Parking signage should be shown on the drewings to meet the requirements of <br />ICC/ANSI A117.1-2009 section 502.7. <br />Two (2) accessible parking spaces are provide '. and dimensioned on sheet A1.0. <br />Ro[h spaces are dimensioned as van spaces even though only one (1) of the rivo <br />spaces is required to be van accessible. <br />Toilet room partitions and fixture locations shouid be dimensioned in plan and elevation <br />for minimum clearances or maximum distances, per ICC/ANSI A117,1-2009 Chapter 6. <br />See A2.6 for updated fixture clearences <br />5. The student break area sink should be shown in elevation to meet ICC/ANSI A117.1- <br />2009 section 606. <br />See A2.6 for new break room plan and elevation meeting requirements <br />6. A vertical grab bar and toilet paper dispenser should be shown and dimensioned on the <br />drawings at the new toilet rooms, per ICC/ANSI A117.1-2009 sections 604.5.1 and <br />604.7. <br />See A2.6 for updated fi�ure dearences <br />Ene y <br />iv.� Building envelope requirements for compliance with the energy code should be shown in <br />the code analysis and on the drawings, per the prescriptive method shown on WS[C <br />table 1"s-1, or the component method, per WSEC C101.4. <br />\ We have chosen the Component method for existing buildings (C101.4.1) and listed <br />required U& R-values for all altered components on the cover sheet and other <br />drawings. <br />Deferred Permits <br />Tenant improvement (for the meuanine), mechanical, plumbing, electrical, sign, and <br />suppression permits should be listed un the cover sheet as deferred permit applications. <br />Tenant improvement, mechanical, sign, and suppression permits will require drawings. <br />T.I. for the Mezzanine, mechanical, plumbing, electrical have been noted as deferred <br />permits on the cover sheet <br />
The URL can be used to link to this page
Your browser does not support the video tag.