Laserfiche WebLink
I'aEc 3 <br />,/2. Egress and emergency lighting should be shown on the drawings, on both levels, per <br />IB� sections 1006.3, 1011.1, and Table 1015.1. <br />a. A discernible path of egress should be shown with illuminated exit signs on the <br />drawings, per IBC sedion 1011.1, where two exits are required. <br />b. Emergency lighting should be shown on the drawings, per IBC sedion 1006.1, <br />�vhere two exits are required. <br />Ex.it signs and illumination are notiv shov✓n <br />Construction <br />� 1. A new guard should be shovm in detail and dimensions for the shell building mezzanine <br />and stairs, per IBC sections 1013.2 and 1013.4. <br />a. Handrail and guard details and dimensions should be shown on the drawings at <br />all buiiding stairs, and at the accessible routes where requir�d, including heights, <br />per IBC sections 1012 and 1013. <br />Requested information has been included on A2.2 <br />�2. Please coordinate the area of the addition (mezzanine) on the site and building data <br />sedion of the cover sheet so that the square footage is consistent. <br />a. Sheet A2.2 indicates a meuanine square footage of 4587 sf, but the cover sheet <br />indicates a square footage of 2000 sf. <br />Cover sheet has been updated to match square footage listed on A2.2 <br />;/3. New ceilings should be shown on the drawings to comply with the seismic installation <br />details of NW Ceiling Institute, attached. <br />Additional detail added to sheet A2.1 <br />; 4. Please coordinate the review oF the access to the roof hatch with AFP1 )im Venturo. <br />Accessibility <br />,,i� i. Please subm+t a written summary of compliance to provide an accessible route for <br />alterations by a minimum of 20% of the costs of the ��Iteration affedinq the area of <br />primary function, per IBC sections 3411.7 and 3411.8. <br />The deferred permit for [he Mezzanine Tenanl improvement will indude an elevator for <br />accessible access to the Mezzanine. All doors within the remodel, along the accessible <br />route and that service the primary function of the remodel will be upgraded to lever type <br />handles. The new sink in break room 81�5 will be accessible. All new Fixtures, including <br />water closets, lavatories, drinking fountains, etc will be accessible. <br />,� 2. Piease identify the existing or new accessible entrance on the drawings, per IBC section <br />3411.6. <br />a. Please indude details, referenced on the plans, for the pedestrian access to the <br />accessible building entrances served, per IBC section 3411.8.1. <br />b. To meet the requirements of a primary accessible entrance, please include <br />details on the following, where applicable: ramps, handrails, pull and push side <br />dimensions on the doors, and ilxesholds. <br />