3. New ceilings should be shown on the dravaings to comply with thc seismic installation <br />details of NW Cei!ing Institute, attached. <br />.s�. Please coordinate the review of the access to the roof hatch with AFM ]im Venturo. <br />Accessibility <br />✓ 1. Please submit a written summary of compliance to provide an accessible route for <br />alterations by a minimum of 20% of the costs of the alteration affecting the area of <br />primary function, per IBC sections 3411.7 and 3411.8. <br />,/ 2. Please identify the existing or new accessible entrance on the drawings, per IBC section <br />3411.6. <br />a. Please include details, referenced on the plans, for the pedestriar <br />accessible building entrences served, per IBC sedion 3411.8.1. <br />b. To meet the requirements of a primary accessible entrance, <br />details on the following, where applicable: ramps, handrails, pull <br />dimensions on the doors, and thresholds. <br />access to the <br />please indude <br />and push side <br />f 2. Within the property line, ramp, sidewalk, and stair widths should be dimensioned on the <br />drawings to be a minimum of 44 inches, per IBC section 1101.Z.2, wher they are part of <br />the accessible route, per IBC sedion 1104.2. <br />� 3, New accessible parking spaces should be dimensioned on the drawings per the <br />requirements of IBC Chapter il, to include the required van space, per IBC section <br />1106.5. <br />a. Access aisles should be dimensioned per ICC/ANSI Ai17.1-2009 section 502.4. <br />b. Parking signage should be shown on the drawings to meet the requirements of <br />ICC/ANSI A1i7.1-2009 section 502.7. <br />J 4. Toilet room partitions and fixture locations should be dimensioned in plan and elevation <br />for minimum clearances or maximum distances, per ICC/ANSI A117.1-2009 Chapter 6. <br />�. The student break area sink should bc shown in clevation to meet ICC/ANSI A117.1- <br />2009 section 606. <br />✓ 6. A vertical grab bar and toilet paper dispenser should be shown and dimensioned on che <br />drawings at the new toilet rooms, per ICC/ANSI A117.1-2009 scctions 6045.1 and <br />604.7. <br />Ene�r9� <br />�I,�� (1./Building envelope requirements for compiiance with the energy code should be shown in <br />,�'1�r.. > v the code analysis and on the drewings, per the prescriptive rnethod shown on WSEC <br />�`,� �Q�\ table 13-1, or the component method, per WSEC C101.4. <br />� �d� Deferred Permits <br />S� 1. Tenant improvement (for the mezzanine), mechanical, plumbing, electrical, sign, and <br />suppression permits should be listed on the cover sheet as deferred permit applications. <br />Tenant improvement, mechanical, sign, and suppression permits will require drawings. <br />