My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
930 N BROADWAY 2018-01-01 MF Import
>
Address Records
>
N BROADWAY
>
930
>
930 N BROADWAY 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/3/2018 8:58:21 AM
Creation date
1/24/2017 1:09:33 PM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
930
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
253
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Puecic wv�z�r.� <br />May 10, 2011 <br />Mr. Gary Harris <br />SRG Partnership, Inc. <br />110 Union Street, Suite 300 <br />Seattle, WA 98101-2087 <br />Sent via e-mail <br />�/�u/i� <br />Project: New Nursing Buiiding-Everett Community College <br />]ob Address: 930 North Broadway <br />Plan Review No: B1103-013 <br />Dear Mr. Harris, <br />In response to your application for �uilding conslruction permit, the plans <br />have been examined and you are advised that a permit cannot be issued <br />until the Following issues are resolved. Please submit two sets of revised <br />plans and details with a response letter, which indicates where each item in <br />this correction letter is addressed on the plan set. Upon resubmission of the <br />drawings, your application will be 9iven priority and plan review will resume. <br />Gen ral comments <br />�C 1� The atrium requires separation from adjacent spaces of a one hour fire <br />barrier, or a horizontal assembly, or both, per IBC section 404.6. <br />Please show how the applicable requirements of IBC sections 404, <br />707, and 712 have been met on the drawings. <br />7_. Piumbing fixture calculations should be shown on the drawings to meet <br />the requirements of IBC chapter 29, including the occupancy load <br />calculations based on the requirements of this chapter. <br />3. The reFlected ceiling plan drawings should include a legend to support <br />drawing locations of the symbols for exit signs per IBC section 1011.1, <br />emergency exit lighting per IBC section 1006.1, and tactile exit signs <br />per IBC section 1011.3. <br />4. In order to eliminate H occupancy categories from this building, please <br />indicate the material, class, storage amount, use and system of <br />hazardous mat�rials posing a physical or health hazard, per IBC tables <br />307.1(1) and 307.1(2). <br />5. If the 22 types of one hour partitions listed on sheet A621 are not <br />used on this project, please cross out the specific partition types th�t <br />are not referenced on tlie plans. <br />�NGINEERING I PUBLIC SERVICES DIVISION • 3�00 Cedar Street • Everett, WA 98201 •(425) 257-8800 • F� ` <br />
The URL can be used to link to this page
Your browser does not support the video tag.