My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
930 N BROADWAY 2018-01-01 MF Import
>
Address Records
>
N BROADWAY
>
930
>
930 N BROADWAY 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/3/2018 8:58:21 AM
Creation date
1/24/2017 1:09:33 PM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
930
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
253
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
19.The urinal height should be dimensioned on the drawings as 17 inches <br />maximum above the floor, per ICC/ANSI A117.1-2003 section 605.2. <br />20.The accessible water closet height should be dimensioned on the <br />drawinys as between 17 and 19 inches maximum above the floor, per <br />ICC/ANSI A117.1-2G03 section 604.4. <br />21.Door hardware should be identified on thc door schedule and should <br />not require tight grasping, tight pinching, or twisting, per IBC sedion <br />1008.1.9.1. <br />22.Pull and push side dimensional maneuvei ing dearances at manual <br />swinging doors should be shown on the dra�vings, per ICC/ANSI <br />A117.1-2003 figure 404.2.3.1 as required by IBC section 1103. <br />a. Doors 140A, 165A, 183A on sheet A404 do not appear to have <br />18 inches clear on the pull side, per ICC/ANSI A117.1-2CO3 <br />Figure 404.2.3.1 (a) to egress from the space. <br />b. Several patient exam rooms do not appear to have the 60 inch <br />maneuvering clearance required, per ICC/ANSI A117.1-2003 <br />Figure 404.2.3.1 (a) to egress from the space. <br />23.Accessibility details should be shown at seating, bars, counters, and <br />points of sale, per ICC/ANSI A117.1-2403 chapter 9. <br />Energy <br />1. The minimum requirements to comply with Washington State Energ;� <br />Code 2009 should be shovan on the drawings, to include the R-value of <br />insulation at the roof, walls and heated floors, windows and doors, <br />lighting. Ali supporting worl<sheets and calculations should be <br />submitted for review. <br />These comments address building issues only. Revisions or additions may be <br />required by other departments (Utilities, Public Works, or Planning). Code <br />references cited include the 2009 Intemational 8uilding Code (I8C), the 2006 <br />Washington State Energy Code (WSEC), and the 2003 Accessible and Usable <br />Ciuildings and Facilities A117.1 (ICC/ANSI). All codes referenced, as adopted <br />by the City of Everett, should indude cunent revisions by the State of <br />Washington. <br />
The URL can be used to link to this page
Your browser does not support the video tag.