Laserfiche WebLink
Meg Haiey <br />July 18, 2011 <br />Page 9 of 10 <br />14. The tuming space wilhin the toilet rooms should be dimensioned, per ICC/ANSI A117.1-2003 <br />section 603.2.1. <br />Response: A 5 foot diameter dashed circle representing the required tuming space in <br />accessible restrooms is shown on the floor plans as well as the enlarged plans on <br />sheets A401 and A404. <br />15. On plan detail 1/A401, the centerline o'the women's room accessible water closet shouid be <br />dimensioned as b�tween 16 and 18 inches from the side wall, per ICCIANSI A117.1-2003 <br />section 604.2. "I'he location of all water Gosets in the clinic shoutd be dimensioned on Ihe <br />drawings. <br />Response: The centerline of all toilets in accessible sWils and toilet rooms are <br />dimensioned as 1'-6" from their adjacent walls. See sheeis A401 and A404. <br />16. The vertical grab bar should be shown in elevation in the accessible water cioset <br />compartment, per ICCIANSI A117.1-2003 section 604.5. All grab bar dimensions l,vertical and <br />horizontal) should be shown on the drawings to compiy with per ICC/ANSI A117.1-2003 figure <br />604.5.1. <br />Response: Grab ba� locations are shown in the Typicai Mounting Heights elevation <br />drawing on 21/A427. <br />17. The toilet paper dispenser in the accessible water closet compartment should be shown on <br />lhe drawings to comply with ICC/ANSI A117.1-2003 sedion 60A.7. <br />Response: Toilet paper dispensers are shown in plan on sheets A401 and A404 and <br />elevated as to the requfred height above finish floor on 21/A427. <br />18. The lavatory heighl should be dimensianed on the drawings as 34 inches maximum above the <br />floor, per ICC/ANSI A117.1-2003 section 606.3 in toilet rooms, ciassrooms, labs, and break <br />rooms, per IBC 1109.2.3. <br />Response: Lavatory heights are shown in the Typical Mounting Heights elevation <br />drawing on 211A427. <br />19. The urinal heighl should be dimensioned on the drawings as 17 inches maximum above the <br />fioor, per ICC/ANSI r�117.1-2003 section 6052. <br />Response: Urinal heights are shown in the Typicai Mounting Heights elevation drewing <br />on 211A427. <br />20. The accessible wa:er cioset height should be dimensioned on tho drawings as between 17 <br />and 19 inches maximum above the Floor, pe; ICCIANSI A117.1-2003 section 604.4. <br />Response: Wator closet heights are shovm in the Typical Mounting Heights elevation <br />drawing on 21/A427. <br />21. Door hardware should be identified on the door schedule and should not require tight <br />grasping, tight pinching, or twis:ing, per IBC section 1008.1.9.1. <br />Response: All door hardware specified for this project in is complianco with 1008.1.9.1. <br />See attached specifications. <br />