My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2320 CALIFORNIA ST SNO CO PUD WAREHOUSE 2018-01-01 MF Import
>
Address Records
>
CALIFORNIA ST
>
2320
>
SNO CO PUD WAREHOUSE
>
2320 CALIFORNIA ST SNO CO PUD WAREHOUSE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2019 3:44:29 PM
Creation date
1/24/2017 8:11:39 PM
Metadata
Fields
Template:
Address Document
Street Name
CALIFORNIA ST
Street Number
2320
Tenant Name
SNO CO PUD WAREHOUSE
Notes
WAREHOUSE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
143
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SNOBOMI6H COUNTY PUD �1 <br /> HEADQUART6RS SIPIINSION i RBNOVATION <br /> MEETINO OF 30/$1 �T TR11 <br /> October 26, 1992 <br /> Thoee Present• <br /> Rod Williame TRA 258-8241 <br /> John Haekell TRA 224-4712 <br /> Jeff 9orek TBC 547-0144 <br /> Don Hoopengarner TBC 547-0144 <br /> Pete LeClair HPCC 251-0221 <br /> Ernie Ward Vallley Elec 424-6602 <br /> Ed Edlin Martina 483-3220 <br /> Sam Preeton Everett F.D. 259-8726 <br /> Tim Tyler Everett Sldg. 259-8810 <br /> Chuck Hartung TRA 682-1133 <br /> Craig Thompeon PUD 258-8606 <br /> Terry Chrietian TRA 224-4724 <br /> Cindy Wilson TRA 224-4714 <br /> Clint Squire HPCC 388-0230 <br /> Pete Piza GSS 622-6545 <br /> Thie meeting was held to go over the Fan Control Panel and <br /> related iesues . It was �atermined that ecope iteme would be <br /> addressed at a future date. A guideline for the meeting wae a <br /> letter sent to the architect by Clint Squire which originated at <br /> Martina. (Since items 1, 2, 3, 5 were ecope releted, they were <br /> not addreseed) . <br /> Item 4: Would the FCP remain ae drewn on diagram 93. 41 or would <br /> it be eplit between the office building and the warehouee? <br /> Conclueion: A single FCP will be located downetaire in the <br /> control room. In addition, the 4 fane in the exieting building <br /> will be added to the FCP. <br /> Item 6 : How many fire alarm output aignals will be presented to <br /> the control syetem for euto emoke evacuation? Will there be a <br /> need to heve several zonee requirinq a different emoke ovacuation <br /> echeme than is deecribed in 15985-5 under Atrium Smoke Purge? <br /> Conclusions one general fire alarm eignal will be eent from the <br /> fire alarm panel to the Staefa Control Syetem to initiate the <br /> Atrium Smoke Purge. Upon general alarm: Atrium goes into emoke <br /> evac mode, all other fan eysteme will ehut down. Outside air <br /> intake dampere and exhauet dampere open, and the recirculation <br /> dampers close. <br /> Item 7 : If emoke were to be sensed at one of the duct mounted <br /> emoke detectora end the AHU were elint down ae celled out in <br /> 15985-3, would a command to run from FCP override the emoke <br /> detector(s) and allow the supply or return fan to run7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.