Laserfiche WebLink
� . _ _ <br /> � <br /> CEOTECHNICAL �NGINEERING STUDY <br /> . Light Industrisl Ware House <br /> 2424 Casino Road <br /> Everett, Washington <br /> . E-4688 <br /> . INTRODUCI70N <br /> . Project Descrintion <br /> Ttie property is located north of Casino Road at 2424 Casino Road, Everett, Washington ;�� <br /> (approximately as indicated on the Viciniry Map, Plate 1). The control center for General �; <br /> rTelephone is located on the adjacent property to the east. An AT&T fiber optic work % <br /> stadon is located on the adj:. •nt property to the west �: <br /> �� <br /> ! At the Ume our study was performed, the site, proposed building location and our exploration �; <br /> locadons were approbmately as shown on the Test Pit Locadon Plan, Plate 2. <br /> rThe purpose of this study was to explore the enicting subsurface conditions at the site and <br /> to develop geotechnical rernmmendations for the proposed site development based on our <br /> findings, <br /> � The office and warehouse swcture will enclose about 65,000 square feet. The structure is <br /> to be about twenty-�ive 25 feet high with an office meuanine. Mcthod of construction is to <br /> � be rnncrete tilt-up with a slab-on-grade. Finish floor elevation is to be about EL 668 to EL <br /> 669. A truck 6eight loading dock will be located along the westem side of the building. <br /> Parking is to be located west of the structure. Up to seven feet of fill may be needed to <br /> � bring the site to grade. <br /> According to the Architect, maximum total dead plus live loads are expected to Ue as folluws: <br /> � • Wall loads - 3.5 kips per lineal toot <br /> • Column loads - 40 to SO kips ' � <br /> , • Slab loads - 500 pounds per square foot (ps� <br /> If any of t6e above design criteria change, we should be consulted to review the <br /> recommendntions contained in this report. In any case, we recommend that Eanh <br /> � Consultants, Inc. (ECI) be retained to perform a general review of the 5nal design. <br /> � Scope of Services <br /> We pedormed this study in general accordance with the scope of services outlined in our <br /> ' February 28, 1990 proposal. On this basis, our repon addresses: <br /> � <br /> 1 Eerth Consultants, Inc. <br />� _ <br />