My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5000 CHINOOK DR 2016-01-01 MF Import
>
Address Records
>
CHINOOK DR
>
5000
>
5000 CHINOOK DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2017 4:23:35 AM
Creation date
1/26/2017 4:23:08 AM
Metadata
Fields
Template:
Address Document
Street Name
CHINOOK DR
Street Number
5000
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. . �- �, <br /> Roger Olin <br /> Plan Check#54259 <br /> Febrvary 25, 1997 <br /> Page 2 of 3 <br /> 6. The spacing of required braced wall panels on the back wall exceeds the allowable (25'-0" <br /> O.C.). <br /> 7. Provide double joists under interior braced wall panels (BWP) when parallel to IBWP, <br /> and solid blocking under wall when IBWP is perpendicular to floor joists. Show blocking <br /> and double joists on plans. <br /> 8. Provide braced wall panels as required by Section 2326.4.1 UBC. Buildings shall be <br /> provided with exterior and interior braced wall lines. Spacing shall not exceed 34 feet on <br /> center in both the longitudinal and transverse directions in each story. The spacing of <br /> IBWP on the upper floor exceeds 34 fect at kitchen/living room. IBWP are non existent <br /> at the front of the upper floor and the entire lower level has none. Show all required <br /> braced wall panels on plans <br /> 9. Provide interior/exterior stair detail(s). Label all components including: <br /> a. Minimum rise of 8" (203mm) and a minimum run (tread) of 9" (229mm) varying <br /> not more than 3/8" (9.Smm). <br /> b. 1vlinimum width of 36" (914mm). <br /> c. Minimum hendroom of 6'S" (2032mm) (1006.2). <br /> d. Framing (stringer size, bracing connections, footings). <br /> e. Enclosed useble space under stainvay requires one-hour construction on <br /> enclosed side (5/8" type "X" Gyp board with framing at 16" O.C. (406mm) <br /> max.). (1006.12) <br /> f. Provide continuous handrail for stairways with 4 or more risers. <br /> g. Handrails shall be 34 to 38 inches (864mm to 965mm) above the nosing of <br /> treads. <br /> h. Intermediete blusters shall be spaced 4" (102mm) O.C. meximum on open <br /> side(s). <br /> r � <br />
The URL can be used to link to this page
Your browser does not support the video tag.