Laserfiche WebLink
' _.....T � �•'1 <br /> ett <br /> Roger Olin <br /> Plan Check 1l54259 <br /> Febniary 25, 1997 <br /> Page 3 of 3 <br /> i. The hand grip portion of handrail shall be not Iess than 1-1/4" (33nun), not more <br /> than 2" (S l mm) in cross sectional dimension. <br /> j. Return handrail to newcl post or wall. <br /> 10. Provide detail of attic venlilation typc, size, and location. Show thc required net area <br /> calculations essuming approximntely 75% of tlie vent area is net nren unless the actual net <br /> area is given Gom the menufacturer. The req�ired ventilatinn area ratio is 1/150 of the <br /> nttic area or I/300 of attic arca if at least half of lhe venl area is more tlien 3' above eave <br /> vents (providing the remaining portion of the vent area). Opening to have 1/4" (6.4mm) <br /> corrosion, resistant metal mesh covering. (1505.3) Vented blocking shall not <br /> compromise ihe sWctural integrity of she��r transfer, roof diaphragm to sl�ear wall. <br /> I 1. The IeR elevation slwws a concrete wall all the way to the back of the house, the plan r <br /> view shows a wood framed wall in the same location. Please clarify. <br /> Prepare a response letter showing where each item in this correction letter is addressed on the <br /> pinn sel. <br /> Upon resubmittal of the epplicntion and site plans, your application will be given priority and plan <br /> review will commence. <br /> All required submittals shall be of sufficient detail and contain sullicient information to ensure that � <br /> tlie proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> ��� <br /> Jef}'Heilman <br /> Development Technician <br /> r��:��in-s�u�.a���(r�-=i <br />