Laserfiche WebLink
23. DumPsters over 1.5 cubic yards capacity shall be located a minimum of five feet from the <br /> building [UFC 1103.2.2, 1994 Edition] <br /> 24. M approved automatic suppression system shall be provided as required by Ciry <br /> Ordinance No. 1902-92, Chapter 16.76 of the Everett Municipal Code. <br /> Plans for any such system must be submitted to the Building Department and the Everett <br /> Fire Department for examination and approval. Such plans must include plans for the <br /> underground meins that will supply the sprinkler system. <br /> As of January, 199i, sprinkler system pertnits are issued by the Building Department. <br /> Plan review fees arc assessed by the Building Department. No fec is assessed by the Fire <br /> Depertment. <br /> Above ground sprinkler pipin� shall be hydrostatically tested es established in NFPA <br /> Standard 13. Underground p�p�ng shall be hydrostaticaly tested and flushed as established <br /> in NFPS Stendard 24 for private fire mains. All such tests must be witnessed by a Fire <br /> Department inspector. Call 259-8710 to make an appointment for inspection. <br /> Contractors'mwteriels and test certificates must be submitted to the Everett Fire <br /> Depertment prior to issuance of any Certificates of Occupancy. <br /> Call 259-8720 for more infortnation. <br /> 25. M approved fire alartn system ahell be Qrovided aa required by City Ordinance No. 1902- <br /> 92, Chepter 16.76 of the Everett Municipal Code. <br /> Plans for such syatem shall be submitted to the Firo Marshal for review and approvel prior <br /> to installation. Submittal shall include cut sheets of all equipment intended for use. <br /> Appropriate trip tests, witnessed by a Fire Department inspector, shall be perfortned <br /> elong with a certificate of completioq prior to final acceptance of the system. <br /> Fire alarm systcros shall be installed according to NFPA Standard 72. <br /> F've alartn systems shell be installed under pertnit of the City of Everett Building <br /> Department. Electrical inspections and approvsl ere required prior to calling for <br /> acceptance tests. Ca11259-SS 10 for pemtit infortnation. <br /> 26. A portable 6re extinguisher with a minimum UL ratin�of 2-A:10-BBC shell be provided <br /> within 75 feet travel distance on each floor of all portions of each building during <br /> construction and prior to cecupancy. <br /> 27. Fire lanes must be provided as required in Everett Municipal Code 46.44. Fire Ianes must <br /> be identified by red curbs with white stenciling stating "NO PARKING- FIRE LANE" <br /> and vertical signa stating"NO PARKING-FIRE LANE -TOW AWAY ZONE." <br /> Location must be approved by the Fire Marshal. <br /> 28. The premises must be clearly identi6ed by address et the street entry. Each building must <br /> be clearly identified so as to be visible and legible from the access road. Each suite must <br /> be clearly identified so as to be visible and legible from the access road. <br /> 6 <br />