My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-26 2018-01-01 MF Import
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
3003 W CASINO RD BLDG 40-26 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 11:02:20 AM
Creation date
1/26/2017 8:26:20 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Imported From Microfiche
Yes
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
b. Sectlon F/1S506 is cut near R-3. It seems it should be cut Iooking <br /> to the east rather than to the we5t. • <br /> Section F/1S506 has "oppos�te hand" added, Issue "B" 3-30-92. <br /> 41 • Sheet 1S504. Sectlon H/TNS501 Is cut N.8-6. It appears it should be cut <br /> looking to the south rather than to the north. <br /> Will revise Section H/TNS501 to look south. <br /> 42 - Section B/1S510. Based on the 5'-8" opening dimenslon shown In Section <br /> G/TNS501 and the computatlons It appea�s that efther the sectlon through <br /> the cover needa to be cut at 90 degrees to the way it is now cut or the <br /> dimenslona of the Ild fllpped. <br /> Cover length of 6'-7 3/4" (6'-0" clear span) has main reinforcing and stirrups <br /> shown correctly in Section B/iS510 as is. <br /> 43 - Detall 8/1S516. Based on the relnforcing shown in Sections p '1S516 and <br /> C1S515 it appears "Sim:' should be appended to the C/1S515 sectlon <br /> mark In thla detail. <br /> Will add "Sim" to Section C/1S515. <br /> 44 - DetaU 7/1S517. It appears Section A/1S517 should be cut looking the <br /> opposite directlon. <br /> Direction of Section A/1S517 has been revised, Issue "B" 3•30-92. <br /> 45 - Section A/1S517. Is additional relnforcing required around the opening In <br /> the slab? <br /> Will add 2 - #5 x 9'0 @ 3" top and bottom at west side of 3'-4" x 3'4" airduct. <br /> 46 - Sectlon A/TNS500. Section A/1S511 is referenced tor the track beam <br /> relnforcing. It appears it would be better to reference Section G/1 S512 <br /> instead. <br /> Section A/TNS500 - will revise to refer to Section G/1S512 rather than <br /> A/iS511. <br /> 47 - Section A/TNS504. It seems the length of the bars in tha utility trench <br /> root which run parallel to the trench should be Indicated, or a note such <br /> as "eMent to first Construction jofnY' be added. <br /> 2 <br />