My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 4TH FLOOR 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
1321
>
4TH FLOOR
>
1321 COLBY AVE 4TH FLOOR 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 8:41:42 AM
Creation date
1/26/2017 10:21:44 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
4TH FLOOR
Notes
PROVIDENCE EVERETT MEDICAL CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> ` 3 <br /> K o > <br /> r � 9 g <br /> y �' e a <br /> � V a z° <br /> A 30 � Not Approved 11/26/02 - Provide revised drawings locating the toilet paper <br /> dispensers next to the water doset and not on the back wal! as shown on Sheet 7.03 <br /> Elevations 8 &9 and Sheet 7.04,Elevations 1, 2, 3, & 5. <br /> WAC 246-?2G-405(2)(i), a�id WAC 246-320-345(1) <br /> Approved Ol/13/03-Drewings revised to show toilet paper dLs;pensers next to <br /> the water closeG <br /> A 31 � Not Approved 11/26/02- Provide revised drawings identifying the use of the rooms <br /> east of Grid 6B if they will no longer be providing obstetric services. If they are <br /> unassigned, then they will be wnsidered slorage rooms with the nced for.s one-hour <br /> occupancy sepazation including one-hour rated doors. WAC 246-320-SO:i(2)(b), <br /> WAC 246-320-525(2), and Section 302.4 and Table 3-C, Uniform Building Code <br /> Approved OV13/03-Revised drawings note that these rooms 8381 B384,B399 <br /> and rooms east of Grid 2B will be used for oftices. <br /> A 32 0 Not Approved I 1/26l02 - Provide revised drawin�s coordinating floor plan Sheet <br /> A23BE and Interior Elevation Sheet AZ02 for Patient Bath B352 and B353, and <br /> between Sheet A23C and Interior Elevation Sheet A7.05 for Patient Bath C326. <br /> Approved 0 U13/03- Revised drawings show Ooor plans and interior elevattons <br /> coordinated ior these rooms. <br /> A 33 0 Not Approved 11/26/02- Provide revised drawings showing that the grab bar at the <br /> side of the water closet in Patient Bath B353,Toilet B347 —if patient accessible, <br /> Patient Toilet B304, and all patient room toilets in Wing 3C extends at least 18 <br /> inches beyond the water closet. WAC 246-320-525(7)(h)(ii)(B) <br /> Approved Ol/13/03 - Revised interior elevations Sheets A7.03,A7.04,and A7.05 <br /> show 18-inch dimension added. <br /> A 34 0 Not Approved L 1/26/02-Provide revised door hazdw:ue for poor 8355. Hardwane <br /> Group#13 dces not provide for self-closing of bolh doors as is required for a rated <br /> door assembly opening to the corridor. WAC 246-320-525(2), and Section <br /> 10043.43.2.1, Uniform Building Code <br /> Approved Ol/13/03- Revised Door Schedule notes thet both doors tor poor <br /> B355 assembly to Linen B355 in Corr.B301 shall be equipped with a closer. <br /> A 35 x❑ Not Approved 11/26/02 -Fcovide revised door hazdware for poors C336,C337 and <br /> C339. Hardware Gruup#14 dces not provide for a rated door assembly with closers, <br /> positive latcl�es, etc. WAC 24G320-525(2), and Section 10043.4.3.2.1, Uniform <br /> Buildiug Codc <br /> Pzge 9 of I I Plan Review Comments for Project M 6345 <br /> Review Kcy: A=Arehirea P=Pire&Li(e Sefety S=Saniiarian M=Mxhanical/Elatrical C=Conforcnce Nole <br /> ��f <br />
The URL can be used to link to this page
Your browser does not support the video tag.