My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 4TH FLOOR 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
1321
>
4TH FLOOR
>
1321 COLBY AVE 4TH FLOOR 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 8:41:42 AM
Creation date
1/26/2017 10:21:44 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
4TH FLOOR
Notes
PROVIDENCE EVERETT MEDICAL CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• � <br /> � C� � <br /> ~ '� 3 � <br /> > <br /> � � � z <br /> z" u° a z' <br /> ?�5.1 � Appro�ed Ol/13/03 • Door Hardware Schedule revLsed to note that Dours C336 <br /> and C339 shall be twenty minute rated assemblies. <br /> 35.2 � Not Approved Ot/13/03 - Alcove C337 shall not be used fur linen storage unless this <br /> area is sepazated from the rated corridor by ratcd door and wall assemblies. <br /> Approved 07/20/03—Revised Sheet A2.3C has chenged the title of this alcove <br /> from linen storage to equipmenl storage. <br /> A 36 � Not Approved I 1/26/02 - Provide revised drawings and door sciredule showing each <br /> patient room door with a minimum 3'-]0"clear opening without the need to activate <br /> the breakaway feature. WAC 246-320-525(2)(d)(i) <br /> Response states that an exemption request has been submitted for this item. <br /> Approved OT/06/03—Per interpretation,door meets intent of rule,no e-empHon <br /> required. <br /> /1 37 � Not Approved 11/26/02- Provide revised door schedule showing that the sliding <br /> glass patient room doors opening to the rated corridor in Wing 3C are tight fitting, <br /> smoke- and draft-control assemblies with positive latches. WAC 246-320-525(2), <br /> and Section 1007.5.4(6), Uniform Building Code <br /> Approved OU13/03- Revised Door Schedule on Sheet A8.04 added note for the <br /> doors opening to the corridor be tight 6tting,smoke-and draf�t-control <br /> assemblies with positive IatcMes. <br /> A 38 O Not Approved i l/26/02 Provide revised drawings removing the non-rated cabinets <br /> from corridor C336 or explain how they aze allowed by the code. <br /> WAC 246-320-525(2), and Section 1004.3.4.3.1, UniCorm Building Code <br /> Approved Ol/13/03- Revised drawings show non-rated cabinets removed from <br /> Corridor C336. <br /> A 39 0 Not Approved I 1/26/02-Provide revised drawings providing at least a 4'-0"cleaz <br /> spacc along both sides of the patient bed in Patient Room C312 and C346. An <br /> exemption may be requested explaining why it is to the patients henefit that the <br /> conf guration shown with a struclural column and power column preventing access <br /> to the patient from one side of the bed. WAC 246-320-725(3)(c)(i) <br /> 39.1 Not Approved 01/13/03 - Revised Sheet A0.61S does not provide a dear passage for <br /> a transition ftom the side clearance to the end clearancc requirements. Clearance <br /> from the power column and structural column are not thc only issues but also ho•.v <br /> the wall of the adjoining patient room and wall of the monitoring station encroach <br /> into required maneuvering space. <br /> Approved 03/21/03-Exemption granted,see CRS #6345-005. <br /> Pagc 10 of I 1 Plan Review Comments for Project#6345 <br /> Rer�ew Kcy: A=A¢hitecl F=Pire&Lde Safe�y S=Sanitanan M=Mechanical/ElecMcal C=Conferente Note <br /> `C.J' <br />
The URL can be used to link to this page
Your browser does not support the video tag.