My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2613 COLBY AVE 2018-01-01 MF Import
>
Address Records
>
COLBY AVE
>
2613
>
2613 COLBY AVE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/3/2018 9:06:05 AM
Creation date
1/27/2017 3:13:15 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2613
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Subject: Proposed Petite Sweet Bakery, 2613 Colby Ave, Everett <br /> April 20, 2012 <br /> Page 2 <br /> 9. When splashguards (partitions, walls and/or equipment ) are provided on both sides of a handwash <br /> sink the distance between the splashguards must be at least 18 mches apart (shoulder width) to <br /> allow proper access to the handwash smk. <br /> 10. Water heate�s must be of sufficient size to provide hot water to dishwasher and/or scullery sinks <br /> and at the same time provide hot water to all handwash sinks. <br /> 11. I?ot water must be available to all handwash sinks within 15 seconds. The hol water for the facility <br /> must not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperationai <br /> inspection. This is required so that proper testing of the 15-second time requireme��t for hot water <br /> availab�lity can be completed. <br /> 12. All food service equipment, both new and used, must be listed by the National Sanitafion <br /> FQundation (N�r) or equivalent for its intended use. Used and new refrigeration must be capable of <br /> hoiding food at :emperature of 41°F or below. <br /> 13. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed <br /> food service establishment. Used equipment must be clean, in proper operating condition, and in <br /> good repair. Used refrigeration must be capable of holding at a temperature of 41°F or below. <br /> 14. Extra wall protection is required on walis behind all sinks, including restroom handwash sinks, and <br /> food preparation counters and tables. A 16-inch high backsplash of plastic laminate, fiberglass- <br /> reinforced plastic or equal is acceptable. A backsplash higher than 16 mches is required on the wall <br /> behind counter top equipment taller than 16 inches. Floor to ceiling protection is required on the <br /> wall behind dishwashers. Wall protection behind mop sinks must cover the entire splash zone. <br /> Plastic coated hardboard is not acceptable. <br /> 15. All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas muct <br /> be surfaced with a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw <br /> cuts and the like in concrete floors in all areas, including customer seating areas, must be filled and <br /> sealed so as to provide a smooth and cleanable surface. <br /> 16. The ceiling above the food preparation areas must be non-perforated, nonabsorbent, smooth and <br /> easily cleanable. <br /> 17. Cabinet shelving must be nonabsorbent, smooth and easily cleanable. (Self stick vinyl or other type <br /> surfaces are not acceptable) <br /> 18. All light fixtures in food preparation and storage areas must be provided with covers and <br /> shatterproof bulbs. Hot hold unit heat lamps must be provided with shatterprooi bulbs. <br /> 19. Plumbing must meet state and local codes. <br /> 20. The ventilation system shall be installed and operated to meet applicable building, mechanical, and <br /> fire codes. <br /> 21. Only one food preparation sink is indicated on the floor plan. Because of this, onty vegetable <br /> preparation will be allcwed at this sink. No rinsing or thawing under running water of raw meat, <br /> poultry, and/or seafood will be allowed without the installation of an additional and separate food <br /> preparation sink. If installed, the location of any additional food preparation sink must be approved <br /> prior to installation. The sink must be NSF listed or equivalent and have at least an integral <br /> drainboard. <br /> A preoperational inspection is requlred prior to operating permit issuance and approval to open <br /> for business. At the time of inspection the construction of the f000 service establishment must be <br /> complete and all equipment must be in place and in proper operating condition. Incomplete construction <br /> or equipment operation will result in a $166.00 re-inspection fee. Contact the Food Prop�am oifice a <br /> minimum of one week in advance of the desired inapection date to achedule an appointment for <br /> the preoporational inspection. The preoperational inspection will ensure compliance with the Rules <br /> and Requ'ations of the State Board of Health for Food Service Sanitation. <br /> !\� <br />
The URL can be used to link to this page
Your browser does not support the video tag.