My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2707 COLBY AVE BASE FILE 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
2707
>
BASE FILE
>
2707 COLBY AVE BASE FILE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 3:56:06 PM
Creation date
1/27/2017 5:01:30 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2707
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
September 27, 1993 <br />Mr. Nick Charles <br />NBBJ <br />I I I South Jackson Street <br />Seattle, Washington 98104 <br />PROJECT: EVERETT MUTUAL TOWER [COLBY SQUARE] <br />S.E. CORNER OF COLBY AND EVERETT AVENUE <br />SUBJECT: PRE -APPLICATION PLAN REVIEW <br />Dear Nick: <br />The following is a summary of our pre -application plan review of your plans received on <br />September 1, 1993. This summary addresses building construction issues only. Additional <br />revisions may be required by other departments (such as Public Works, Planning, Traffic <br />and/or Fire). All references refer to the 1991 Uniform Building Code, as amended by the <br />State of Washington and/or the Washington State Energy Code 1991, 2nd edition, unless stated <br />otherwise. <br />I. The least type of construction allowed considering area increases for multiple floors <br />[Section 505(b)], separation on two sides [Section 506(a)l], and automatic sprinkler <br />system installation [Section 506(c)] would be Type Ii F.R. as described in Chapter 19. <br />The total allowable area would be 239,400 square feet. <br />This type of construction would also conform to the requirements of Section 507 allowing <br />160 feet of height and 12 stories. <br />2. The parking floors of the building would be classified as BI occupancies [133 occupancy <br />is not allowed within a building of mixed occupancy per the definition in Section 709(b)]. <br />The retail and office floors of the building would be classified as B2 occupancies. <br />3. According to Section 1903(a) and 1903(b) [also see Section 1807(c)2A] exterior wall <br />construction and opening protection is as follows: <br />West (Colby): noncombustible/unprotected openings <br />North (Everett Ave): noncombustible/unprotected openings <br />East (alley): 'Iwo -hour, fire resistive/protected openings <br />South: three-hour, fire resistive/no openings allowed <br />Please note that wall construction and opening protection are evaluated using the <br />centerline of a public way. Please also note that Table 51 does not apply to buildings of <br />Type I, I1-FR, III an IV construction. <br />4. Elevator lobbies are required at all levels including the parking levels. Section 1807(h)l. <br />i CITY OF EVERETT- 3200 Cedar Street • Everett, WA 98201 • (206) 259-8800 • max (206) 259-8882 <br />ar <br />
The URL can be used to link to this page
Your browser does not support the video tag.