Laserfiche WebLink
r <br /> Mea Haley <br /> From: Meg Haley <br /> Sent: Monday, November 26, 2007 5:09 PM p, <br /> To: 'budnikemail@verizonnet; 'AdamClark`, 'BrentKoos' I�C7�G-(,C.3 <br /> Cc: 'mberona@beronaengineers.com'; 'kath@beronaengineers.com' <br /> Subject: 2814 Colby building permit status <br /> Attachments: 3053_001.pdf; 3056_001 pdf; 3057_001.pdf; 0064_001.pdf <br /> Thank you for making the time to address our remaining questions regarding the use and mechanical design for the tenant <br /> improvement to the basement oi 2814 Colby. Please advise i(the following meeting summary should be corrected (the <br /> action items for the mechanical permit submittal will be senl by e-mail tomorrow). <br /> . A description of how the maximum occupant load will be kept to 49 people by JASE LLC shuuld be submitted to Tony <br /> Lee, Permil Service Manager, COE,for review. The drawings should not show more seating than the maximum <br /> occupant load will allow simultaneously in lhe spa pool area and the lounge area for a total oi 49 people, unless exiting <br /> revisions are made lo the plans as currently drawn. Clarifications may be required to the firsl floor entry area used as <br /> a control point for maximurn occupancy. See attachment. <br /> • A future commercial kitchen with a Type I Hood would require the exiting to be revised to separate the two exits per <br /> code, with a separate corridor. <br /> • The drawings have to slate clearly that the door separating Ihe two lenants in the basemenl(JASE LLC 8 The Full <br /> Gospel Mission Church)will remain unlocked from bolh directions since both tenants require two exits at aU times <br /> from the basement, when the space is occupied Require�exit signage, emergency lighting and panic hardware <br /> �hould be shown on the ptans. <br /> • The doors into lhe shower areas should have a 48 inch deep space between the strike and lhe opposing wall; 54 <br /> inches if a closer is on the door, per ICC/ANSI Figure 4042.3.1 (�. <br /> • Specific materials to control the vapor from the pool and sauna areas should be shown on the architectural drawings <br /> to include the ceiling treatment in addition to the wall and floor treatment. See attached e-mail. <br /> • The new exhaust tans on the roof should be shown to be a minimum ten feet away from tlie existing AHUs, see <br /> attachmentiorreference. <br /> • The drawings should clanfy that the VA wnstruction is utilizing the sprinkler substitution instead of rated floor-ceiling <br /> assemblies. The previous permits have been attached tor reference <br /> --------------------------- <br /> � ,�•. � 1� <br /> 3053_OOl.pdf(2 �956_001.pdf(267 3057_OO1.pdf(1 OD64_OOl.pdf(21 <br /> MB) K�) MD) KO) <br /> M��{�y <br /> Plans Examinc�. City ��f !'.vcrc�tt <br /> :;,-_20CedarS,:ec' ... _ . � - , <br /> Fh-a5�_..=5/-1�,;t1�.. F.ix� � , . �- � . <br /> www_evcrc�twa.or�c Idcfault.aspx71D=�7G <br /> 1 <br />