My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2814 COLBY AVE DOWNTOWN BANYA 2018-01-01 MF Import
>
Address Records
>
COLBY AVE
>
2814
>
DOWNTOWN BANYA
>
2814 COLBY AVE DOWNTOWN BANYA 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/4/2018 7:29:38 AM
Creation date
1/27/2017 7:02:09 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2814
Tenant Name
DOWNTOWN BANYA
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> Mea Haley <br /> From: Meg Haley <br /> Sent: Monday, November 26, 2007 5:09 PM p, <br /> To: 'budnikemail@verizonnet; 'AdamClark`, 'BrentKoos' I�C7�G-(,C.3 <br /> Cc: 'mberona@beronaengineers.com'; 'kath@beronaengineers.com' <br /> Subject: 2814 Colby building permit status <br /> Attachments: 3053_001.pdf; 3056_001 pdf; 3057_001.pdf; 0064_001.pdf <br /> Thank you for making the time to address our remaining questions regarding the use and mechanical design for the tenant <br /> improvement to the basement oi 2814 Colby. Please advise i(the following meeting summary should be corrected (the <br /> action items for the mechanical permit submittal will be senl by e-mail tomorrow). <br /> . A description of how the maximum occupant load will be kept to 49 people by JASE LLC shuuld be submitted to Tony <br /> Lee, Permil Service Manager, COE,for review. The drawings should not show more seating than the maximum <br /> occupant load will allow simultaneously in lhe spa pool area and the lounge area for a total oi 49 people, unless exiting <br /> revisions are made lo the plans as currently drawn. Clarifications may be required to the firsl floor entry area used as <br /> a control point for maximurn occupancy. See attachment. <br /> • A future commercial kitchen with a Type I Hood would require the exiting to be revised to separate the two exits per <br /> code, with a separate corridor. <br /> • The drawings have to slate clearly that the door separating Ihe two lenants in the basemenl(JASE LLC 8 The Full <br /> Gospel Mission Church)will remain unlocked from bolh directions since both tenants require two exits at aU times <br /> from the basement, when the space is occupied Require�exit signage, emergency lighting and panic hardware <br /> �hould be shown on the ptans. <br /> • The doors into lhe shower areas should have a 48 inch deep space between the strike and lhe opposing wall; 54 <br /> inches if a closer is on the door, per ICC/ANSI Figure 4042.3.1 (�. <br /> • Specific materials to control the vapor from the pool and sauna areas should be shown on the architectural drawings <br /> to include the ceiling treatment in addition to the wall and floor treatment. See attached e-mail. <br /> • The new exhaust tans on the roof should be shown to be a minimum ten feet away from tlie existing AHUs, see <br /> attachmentiorreference. <br /> • The drawings should clanfy that the VA wnstruction is utilizing the sprinkler substitution instead of rated floor-ceiling <br /> assemblies. The previous permits have been attached tor reference <br /> --------------------------- <br /> � ,�•. � 1� <br /> 3053_OOl.pdf(2 �956_001.pdf(267 3057_OO1.pdf(1 OD64_OOl.pdf(21 <br /> MB) K�) MD) KO) <br /> M��{�y <br /> Plans Examinc�. City ��f !'.vcrc�tt <br /> :;,-_20CedarS,:ec' ... _ . � - , <br /> Fh-a5�_..=5/-1�,;t1�.. F.ix� � , . �- � . <br /> www_evcrc�twa.or�c Idcfault.aspx71D=�7G <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.