My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2814 COLBY AVE DOWNTOWN BANYA 2018-01-01 MF Import
>
Address Records
>
COLBY AVE
>
2814
>
DOWNTOWN BANYA
>
2814 COLBY AVE DOWNTOWN BANYA 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/4/2018 7:29:38 AM
Creation date
1/27/2017 7:02:09 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2814
Tenant Name
DOWNTOWN BANYA
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2814 Colby building mcchanical permi� status M0710-003 � <br /> Meg Haley <br /> From: Brent Koos(brent@garyparkinson.comJ <br /> Sent: Wednesday, November 28, 2007 3:16 PM n'�G-1���(�O3 <br /> To: Meg Haley <br /> Cc: mberona@beronaengineers.com; kathi@beronaengineers com <br /> Subject: Responses lo issues below_. <br /> Meg; <br /> a. Pool chemicals, if used, will be stored in Storage Room next to the elevator. <br /> b_ The "Minimax" pool heater will be located on the mechanical plans. <br /> c. The pool area will be recalculsted. <br /> d. '�"e existing basement fumace will be repfaced and located in mech�nical room next to the sauna. <br /> e. Wlechanical engineer wiil verify the IMC used. <br /> f. Mechanical drawing will show distance from intake/exhaust to CL of alley. <br /> g. Mechanical drawings will show distances from existing and new AliU units. <br /> --Original Message----- <br /> From: Meg Haley [maiito:MHaley@ci.everett.wa.us] <br /> Sent: Tuesday, November 27, 2007 4:11 PM <br /> To: mberona@beronaengineers.com; kathi@beronaengineers.com; ecnwinc@concast.net <br /> Cc: budnikemail@venzon.net; Adam Clark; Brent Koos <br /> Subject: 2814 Colby building mechanical permit status M0710-003 <br /> Melchor and Kathi, <br /> Very sorry to hear of your loss Melchor. <br /> Kathi, this is the summary I have of inechanical permit issues, most of which we covered in yesterday's meeting. <br /> Please respond or advise if corrections are required. <br /> . l he last correspondence that COE has on file for the requirements for pool chemical storage from Joseph <br /> Dominczyk, P.E., Engineering Consultants Northwesl indicates that this chemical storage should be shown on <br /> the plans per the attached requirements(see attached). <br /> • The minimax pool heater, intake and exhaust should be shown on the mechanical plans, since the equipment <br /> and instaliation were excluded from the pool permit. Intake and exhaust should be indicated on the elevation. <br /> per manutacturer's recommendations(see attached). <br /> . Flease veriry if the Banya Pool Area Calculations dzted October 29, 2007. are no longer applicable, since the <br /> calculations do not inGude the whole basement area in JASE, LLC. <br /> • 7he existing basement furnace should be shown on the plans, if it is siill in use. Reference attached permit <br /> M0403-016, dated March 2004. <br /> • Please verify the proposed IMC Code teing �ised for the design (2003 or 2006). <br /> . IMC 401.5.1 has speci6c requirements for the separation oi intake and exhaust, and distance irom the <br /> center!ine of the alley. Please darify if this is met on Exterior Section A vent openings on Sheet M4. <br /> • The new exhaust fans on the roof should be shown ;o be a minimum ten feet away from the existing AHUs, <br /> per the e-mail sent yesterday on the building permit status. <br /> I I;�X/2007 <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.