Laserfiche WebLink
.- . ,,... ,n <br /> June 4, 1991 <br /> ���Charles B. Ogden, Architect, Ptincipal <br /> Dykeman Architects PS G��/ <br /> v /� <br /> 1602 Hewitt Avenue �j3" _ <br /> Everett, WA 98201 ja <br /> U <br /> Subject: Scotdahl Pro�ect <br /> Colby and Hewitt <br /> Dear Chuck: <br /> The following is an outline of issues and answers relative to this proposal, <br /> ahich is a level of below grade parking ((B-1 UBC occupancy) , a level of B-2 <br /> (USC occupancy) , and a four level s+ngle family residence (R-3 UBC <br /> occupancy). This structure being connected to the existing bank building on <br /> the southaeat corner of Hewitt and Colby. <br /> I. Conetruction Type <br /> A. R-3 occupancies exceeding 3 stories xequire Type I F.R, <br /> Construction (Table 5-D) <br /> B. This limitation is based on the proposed numher of stories and the <br /> limltation of the higheat story on which an occupancy can occur. <br /> II. Elevator Lobby <br /> A. A lobby is required at the B-1 level and the B-2 to serve as an <br /> occupancy separation, which will serve to prohibit smoke and fire <br /> from migrating from one occupancy to another. <br /> .�... •:i.n•rlllsR. .. .!�LTS•Y.°.�n7L:C�:•x� �I�=r.'.•.f`.!Afl7ffPt:'"L1At��Zi%V!RAlti'.LL:S"1AY'DS�C:� , .�ry.1.C'�i7!-t��.1'6�q'iP:� . .'."I'1��9:7R'1L " ti�1 <br />