Laserfiche WebLink
i I <br /> B. A lobby w :d not be required on any R-3 �or. This is based on <br /> a single occupancy and the lack of required fire resistive <br /> Icorridors on these floors. <br />� <br /> III. Stairways <br /> A. The proposed configuration of an open stainray between stories 5 <br /> ar.d 4, lus a stair enclosure transitionin to two stair n <br /> P B <br /> enclosures from story 4 down, does not comply. <br /> 1 <br /> B. One stairway must extend to the roof. (33060) <br /> IV. Automatic Sprinkler System <br /> A. The existing bank buildinb would not require the installation of <br /> sprinklers if an ar.ea separation wall were created on the south <br /> : aide. The wall taould require compliance with Section 505(c) UBC. <br /> B. The propased building would require automatic sprinklers based on <br /> the area and the (:ity's sprinkler ordinance. <br /> V. Building Separation/Exterior Wall Construction <br /> A. Compliance with UBC Sectigw�504 is required. Condition III-A ia a <br /> 1 <br /> portion of this issue. � <br /> J <br /> B. If condition III-A is met and the assumed property line (UBC 504c) <br /> is on the plane of the existing bank building, the exterior wall <br /> of tha would appear to be in compliance <br /> above the roof line of the connecti.ng section. The exterior well <br /> of the pioposed building below the connecting roof line doea not <br /> comply. <br />