Laserfiche WebLink
Subject: Proposed Kama'aina Gnndz, 2933 Colby Ave., Everett <br /> September 21, 2012 <br /> Page 2 <br /> 10. Water heaters must be of sufficient size to provide hot wate, to dishwasher and/or scullery sinks <br /> and at the same time provide hot water to all handwash siriks. <br /> 11. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility <br /> must not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational <br /> inspection. This is required so that proper testing of the i 5-second time requirement for hol water <br /> availability can be completed. <br /> 12. All fond service equipment, both new and used, must be listed by the National Sanitation <br /> Foundation (NSF) or equivalent for its intended use. Used and new refrigeralion must be capable of <br /> holding food at temperature or 41°F or beiow. <br /> 73. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed <br /> food service estabiishment. Used equipment must be clean, in proper operating condition, and in <br /> good repair. Used refrigeration must be capable o( hoiding at a temperature �f 41 For belew. <br /> 14. Extra wall proteclion is required on walls behind all sirks, including restroom handwash sinks, and <br /> food preparation counters and tables. A 16-inch high backsplash of plastic laminate, fiberglass- <br /> reinforced plastic or equal is acceptable. A backsplash higher than 16 inches is required on the wail <br /> behind counter top equipment talier than 16 inches. Floor to ceiiing protection is required on the <br /> wall behind dishwashers. Wall protection behinci mop sinks must cover the entire spiash zone. <br /> Plastic coated hardboard is not acceptable. <br /> 15 Ail (loors in the kitchen, food preparation, food service, food storage, and dishwashing areas must <br /> be surface� with a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw <br /> cuts and the li�e in concrete floors in all areas, including customer seating areas, must be filled and <br /> sealed so as to provide a smooth and cleanable surface. <br /> 16. The ceiling above the food preparation areas must be non-periorated, nonabsorbent, smooth and <br /> easily cleanable. <br /> 17. Cabinet shelving must be nonabsorbent, smooth and easily cieanable. (Self stick vinyl or other type <br /> surfaces are nut acceptable) <br /> 18. All I�ght fixtures in food preparation and storage areas must be provided with covers and <br /> shatterproof buibs. Hot hold unit heat lamps must be provided with shatlerproof bulbs. <br /> 19. Plumbing must meet state and local codes. <br /> 20. The ventilalion system shall be installed and operated to meet appiicable building, mechanical, and <br /> fire codes. <br /> 2 i. Please note; this facility has a limited amount of reach-in refrigeration equipment. Reach-in <br /> refngeration is not designed (or cooling of hot (oods. No advanced preparation of foods that require <br /> coohnq and no coolinq of leitover (oods will be ailowed uniess a walk-in refr!qerator or blast chilier <br /> (rapid temperature pull down refnqerator) is installed or other Healih Distnct approved cooiinq <br /> method is m place. Approvai of any cooling method must be obtained prior to implementation <br /> of any cooling process. Approval of equipment used for cooling and approval of the <br /> pro�osed location of any cooling equipment must be obtained prior to ir.stallation of the <br /> equipment. Piease note that if any approval for cooling of food is given the risk classification <br /> for the establishment v,riii chanqe to a high-risk food establishment and an additional permit <br /> fee for the classification change will be charged. <br /> 22. This establishment has one 3-door upright refrigerator (72 cubic (eet of refriger:iied stor2ge), one 2- <br /> door upright re(rigerator (49 cubic feet of refrigerated storage), and one 1-door upright refriyerator <br /> (23 cubic feet of refrigerated storage). The total proposed refrigerated storage for this establishment <br /> is 144 cubic feet of storage. fliis meets the Health District minimum requiremer.ts. However, If <br /> during routine inspections it is found that the current amou�t of refrigeration is inadequate for the <br /> food storage needs of this facility then tlie number of inenu items must be reduced to a level <br /> acceptable for tre facility's amount of refrigeration. The menu item redu�tion will remain i�� eftect <br /> until such time as additiona� refrigeration and or freezers are installed and approve� by the Health <br /> Gistrict. <br />