My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3332 COLBY AVE 2016-01-01 MF Import
>
Address Records
>
COLBY AVE
>
3332
>
3332 COLBY AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2017 11:05:50 AM
Creation date
1/27/2017 11:04:42 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3332
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
124
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- <br /> �= `� r.� �',_ . . <br /> � <br /> Re; Calvary Baptist Church, 34th ,� Colby, iverett, Washington <br /> An Inspection of the captioned building was made on February 26, 1971 by Pfr. Walter <br /> Cooper, Assistant City Fire Afarshal and Sohn Farrens, Plan Checker for the City of <br /> Everett. The following items were found to be in violation of applicaUle codes and <br /> must be corrected and completed by thc following listed dates. <br /> Lower floor (grade level at rear of buildinR) <br /> 1.The kitchen must be separated from the other portions of the t�uilding by one hour <br /> fire resistive construction. This will require the following: <br /> Completed By <br /> May L0, 1971 a. A one hour wall between the kitchen and the area south of the <br /> kitchen which is used as an exit. A 1 3/4" solid core donr <br /> with self closure and fusiUle link is required from kitchen to <br /> the hall area. <br /> Piay 10, 1971 b. Pass thru to assembly area to be equal to a solid core door. <br /> May 10, 1971 c. Door to assembly area shall be solid core. <br /> April 10, 1971 d. Door to boiler room sha11 be 1 3/4" solid core with self closer <br /> and fusiUle link. <br /> i•iay 10, 1971 e. Noles in walls shall be fire stopped. <br /> Dfay 10, 1971 f. 1 itour ceiling construction. <br /> April 10, 1971 g. Remove exit light over door to boiler room. <br /> March 20, 1971 h, Install 1 - S�b dry chemical fire extinguisher. <br /> April 10, 1971 i. Wooden cabineta over top of electric grille shall be removed and <br /> replaced with an approved metal hood wigh vent. <br /> 2. Exit area (South of Kitchen) <br /> May 10, 1971 a. Shall have 1 hour walls and ccilings. <br /> April 10, 1971 b. Door to storage shall Ue solid core. <br /> c. Exit lite to outside shall remain. <br /> May 10, 1971 d, Install guard rail on side walk outside of door. <br />' March 20, 1971 e. Door to exterior shall have panic hardware. <br /> 3. Boiler Rooms <br /> May 10, 1971 a, Shall have 1-hr w�lls and ceilings. <br /> May 20, 1971 b. Remove exit lite to o�itside. <br /> iMay 10, 1971 c. Install fire dampers in all air duct work penetrating walls or <br /> ceilings. � <br /> May 10, 1971 d. Dampers shall be installed on boiler room side of partition, <br />� i 4. AssemUly Room (EatinR area) <br /> March 20, 1971 a. Remove exit lite over door to kitchen (North end of Kitchen) <br /> March 20, 1971 b. Remove exit lite over pair of doors to stair (East end of assembly <br /> rooml <br /> April 10, 1971 c. Install 1 3/4" solid core door with closer and fusiUle link to <br /> stair hall (North side of. assembly room) <br /> 5. Stair (West Stair) <br /> Atay 10, 1971 a. Remove door and frame to corridor to nortli, <br /> May 10, 1971 b. 1 hour walls and ceilings <br /> May 1D, 19;1 c. Add Z" gyp board to all walls having only z" gyp boacd, Lach <br /> side of walls, <br /> 6. Corridor running East - West near stair. <br /> May 10, 1971 a, Add a 1-hr, door with self closer and fusible link between stair <br /> and main corridor of grade 1eve1 floor. Uoor to swing into new <br /> corridor. <br /> May 10, 1971 b, Add exit lite wir.}� arrow pointing toward outside door. <br /> April 10, 1971 c. Install self closcr and fusiUle linlc on boiler room door. <br /> 7. Main Corridor (Grade level floor) <br /> April 10, 1971 a. Change all hollow core doors to 1 3/4" solid core doors. <br /> March 10� 1971 b. All 1 3/8" solid core doors sl�all be coated with fire retardant <br /> varnisli. <br />
The URL can be used to link to this page
Your browser does not support the video tag.