My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3525 COLBY AVE 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
3525
>
3525 COLBY AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/20/2023 3:53:47 PM
Creation date
1/27/2017 11:59:54 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3525
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
267
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBL/C f�1/O/�K5 <br /> PC �B4E384 <br /> June 13, 1995 - <br /> Page 2 <br /> 4, Plans shall conform with Chapter 5 as follows: <br /> �. Table No. 5-A for wall and opening prote�don (Types II-1 HR, II-N, <br /> and VJ; for other:, see 03 Sections of Part N. <br /> Tt►e north wall must be one hour rated. <br /> lLC�7�1� b. Table 5-B fur occupancy sepazations. <br /> The pazk;ng area and all adjacent office areas around and above must be <br /> separate�i by one hour rated construction. . <br /> �, Table 5-D `or height, number of stories and types of construction. <br /> The building must be fully sprinkled (NFPA 13 system) to allow the <br /> story increase per secdon 507. <br /> A1Cf� 5. Horizontal occupancy separation shall be supporteci with a structural system <br /> having equivalent fire-resistive protection. SecGon 503(b).. <br /> �6. Vertical occupancy separations shall extend through undertloor and atti� areas, <br /> including areas where fire-resistive ceilings are specified. <br /> �19j� 7. Usable space under the first story sha:l be enclosed as required in Section 1703. <br /> Il,bT1:G 8, Attic ventiladon shall be provided per Section 3205(c). Please provide <br /> calculations for all areas including towers. <br /> �. Roof drains shall be connected ta the storm sewer. I <br /> ��p 10. A weather-resistive bazrier must be applied to exterior walls as specific in <br /> Section 1708(a). <br /> V 11. Glass and glazing shall comply with Chapter 54. Type and thickness of glass <br /> must be specified. This item applies to glazing within 24 inches of doors. <br /> �2. The under floor azea must be ventilated for Section 2516(c)6. <br /> CITY OF EVERETT•3200 Cedar Street• Everett,WA 98201 • (206) 259-8800• Fax(206) 259•8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.