Laserfiche WebLink
_ - _ -T • _ <br /> PUBL/C K/O«X5 <br /> : <br /> pc a sa8ssa - <br /> lune 13, 1995 <br /> Page 3 <br /> ylg. F�ciu are required to have a minimum sepacadon of one-half the maximum <br /> diagonal of the building or area served mc•asured in a straight line between <br /> euts. Section 3303(c). <br /> ✓q, Walis and ceilings of corridors are required co be of one-hour firc-resistive <br /> construction. Section 3305(g). f!n azchitectural section through the corridor is <br /> necessary to determine how this is accomplished. <br /> �5. Interior openings into corridors are required to be protected as set forth in <br /> Section 3305(h). Self-closing or automatic closing twenry-minute rated door <br /> assemblies properly gasketed should be provided. Other openings are limited to <br /> 3/4-HR rated fixed glazing and shail not exceed 25% of the area of the common <br /> wall. <br /> �✓16, No openings other than exit doors are permitted within stair enclosures, Sec. <br /> 3309(c). <br /> �17. Stair enclosures must be of one-hour rated conswction. Please provide <br /> construction derails, Section 3309(b). <br /> �18. Elevator shaft walls must be of one-hour rated consWcdon. Please provide <br /> construcdon details. <br /> �„I�j�� 19. All doorways leading to accessible rooms shall have an unobstructed clear width <br /> of not less than 32 inches. Section 3106(j). Tttis applies to doors 7, 14, 21, 26 <br /> & 27. <br /> ►iz0. Accessible doors shall have maneuvering clearances per Section 3106(j)3. 'I7us I <br /> applies to doors 23, 24 and 25. <br /> 21. Please provide engineering calculadons for all retaining walls over 4'-0" high. I <br /> ✓22, Provide detaiis for the guardrails. Maximum rail spacing is 4". <br /> ���1� 23, Provide an exterior stair section. <br /> ✓24. Provide R19 floor insulation, u.60 max. for doors and windnws. <br /> CITY OF EVERETT•3200 Cedar Street• Everett,WA 98201 •(206)259•8800• Fax(206) 259•8856 <br /> - - - - - - -�ve <br />