My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3716 COLBY AVE 2016-01-01 MF Import
>
Address Records
>
COLBY AVE
>
3716
>
3716 COLBY AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2017 12:53:53 PM
Creation date
1/27/2017 12:53:23 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3716
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• v � � . I= <br /> L4u"�d�.•��neNYvll tr.3-00J p176 CCCy) <br /> Aw+>t:i.701I <br /> 6. Emergency escape and rescue openings with a finished siil height below the adjacent <br /> ground elevation shall be provided with a window well in accordance with Section R310Z <br /> IRC. The minimum horizontal area of the window well shali be 9 square feet, with a <br /> minimum horizontal projection and width of 36 inches. The area of the window well shall <br /> allow the emergency escape and rescue openiny ±o be fully opened. <br /> 7. Provide detail/sedion for framing at below grede walls. Show Washington State Energy <br /> Code (WSEC) requirements, framing and fire-blocking. <br /> 8. Provide size and location of all exhaust fans. <br /> 9. Floor plan shall show ail new construction using a diNerent symbol for each wall .rype; new, <br /> existing, and removed walls. <br /> 10. Show location of furnace and water heater (if no furnace, show how all habitable spaces <br /> are heated). <br /> 11. Show location of washer and dryer. Provide minimum 50 cfm fan in laundry vented to the <br /> exterior. <br /> 12. Application does not include mechanical equipment or plumbing that was added/modified <br /> without permits. <br /> 13. Every dwelling unit shall have at least one habitable room that shall have not less than 120 <br /> square feet of gross floor area. <br /> 19. Provide multipie kitchen covenant for this property recorded �vith Snohomish County. See <br /> Planning Department for required covenant. <br /> 15. Label plans as basement, first Floor (cr main Floor) and second Floor. <br /> Please prepare a response letter showiag where each item in this correction letter is <br /> addressed on the plan set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> ���� <br /> Jeff Heilman <br /> Developrnent Technician <br /> 425-257-8976 <br /> Email: jheilman a ci.everett.wa.us <br /> y�atTVMM�NBW1�08-0O1 p7�fi Cdty)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.