Laserfiche WebLink
7. Provide detail(s) of deck construction showing the follov+ing; <br />a. Ledger connection (show what ledger is bolted to) R507.2 <br />b. Stair stringers (quantity, siz�, attachment) <br />c. Rise, run, handrail <br />d. Post to deck connedion (at guardrail) <br />e. Post to footing connection <br />f. Lateral connection per R507.2.3 <br />g. Openings in guardrail shall not ailow the passage of a 4" sphere (openings shail <br />be less than 4'� <br />8. Specify minimum 50 CFM exhaust fan, vented to the e�Rerior in new bathroom and <br />laundry. (Veri(y existing bathroom adjacent to addition has min. 50 CFht exhaust fan). <br />9. Label all braced wall panels on plans per section R602.10 IRC. <br />10. Specify construdion of roof strudure induding of collar ties to rafters, ce�liiig joists to <br />rafters, raRers to top plate and blocking at rafters. (incl. sunroom? <br />11. Provide minimum R-49 insulation in attic. <br />12. Provide minimum 22" X 30" attic access with min 30° dearance over access opening. <br />13. Specify attic ventilation. Show size and location of altic vents. Show ho�v sun room roof <br />is ventilated. <br />14. Show how sunroom is finished. Specify sheathing, moisture barrier, siding, interior fnish <br />material etc... <br />15. Show siding, sheathing on cripple walls at addition. <br />16. Provide u-value oF all new doors in conditioned spaces. <br />17. Provide safety glass in hazardous locatians as defined in section R308 IRC. Show on <br />plans. <br />18. The roof framing plan shows 2 X 6 rafters at 16" O.C. on the sun room, the section <br />shows 2 X 12's at 29" O,C. please clarify. <br />19. Add washer, dryer and 2 exhaust fans to application. (Exhaust fan required to be added <br />in existing bathroom adjacent to addition if not presenC). . <br />S�.UCommon\qencaNHellman�C1310-003 (5805 COlby Ave).aac <br />