Laserfiche WebLink
� � { <br /> ��r Q. rm��� («o���-u��> <br /> lanuary 1±, �lR)� <br /> !'as;c '_ <br /> _'. The mir'mum tn�ad depth for the stairs should be shown as 11" ;is there is no elevator <br /> pro��ided. Scction 10033.3.3 <br /> 3. Each stainva�� rcquin;s a handrail on cach side, as thc seconJ tloor does not have an <br /> elevator. Section 1003.3.3.G <br /> d. At le;u[ one handrail (per ;tairway) must continuc in the direction of travcl a mir.imum of <br /> 1?" past thc top riser and 12" plus one tread depth past the bottom riser. Section 10033.3.6 <br /> �. 'fhe handr.�il a[ the stairs in the Piano Retail spacc shoiild continue to the last .^s�,-. Section <br /> 10(33.33.6 <br /> 6. The storaec. area und�r the stairs in the Piano Retail space should be shown protected as for <br /> one-hour construction. Scction 1003.339 <br /> Accessibilit�• <br /> 1. The van-acccssible parking stall should be shown to bc a minimum of 8 fcct wide with an 8- <br /> foot wide access aisle adjacent to rt (the othcr `standarci' acccss aislc should be shown as 5 <br /> feet minimum). Section I 107.2.2 <br /> '_. Curb cuts should be snown in thc sidcwalk surrounding thc building for accessible travel. <br /> Section : 106.�1.i <br /> 3. Cur6s, guardrails or raised 'bump'-type detectahle warning surfaces should be provided <br /> where the accessible roi�te of travel crosses or ai!joins vehicular areas. Sections 1106.4.8 & <br /> ] 106.17 <br /> �l. The following doors should be provided with the proper maneuvering clearance as noted in <br /> Section 1106.103: Doors #2, 7, 9, 20, 22, 24 & 25. <br /> �. The showers should either comply as transfer or roll-in type—clevations shonld be provided. <br /> Sections 1105.2.1 & 1106.11.10 <br /> G. The centerline of the toiiets should be shown at 18" from the closest wall. The flush contrul <br /> shou!d be shown on the opposite side of the tank From the near wall. Sec[ion 1106.11.5.1 <br /> 7. The height oC the toilets should be shown on the plans (17"-19"). Section 1 IOE.I1.5.2 <br /> 8. The cabinetry oF the lavatories should be relocated such that they do not impinge upan the <br /> minimum GO" tuming radius in the toilet rooms. Section 1106.11.2 <br /> �3 <br />