, ( 4 <br /> Tony Lee <br /> March 7, 2003 <br /> Page 2 <br /> 3. Eacli stairway requires a handrail on each side, as the <br /> second floor does not have an elevator. Section 1003.3.3.6. <br /> '"Revised, see sheet A-2 Floor plans. <br /> 4. At least one handrail (per stairway) must continue in the <br /> direction of travel a minimum of 12" past the top riser and 12" <br /> plus one tread depth past the bottom riser. Section 10�3.3.3.6. <br /> "*Revised, see sheet A-2 Floor plans. <br /> 5. The handrail drail at the stairs in the Piano Fetail space <br /> should continue to the last riser. Section 1003.3.3.6. <br /> ""Revised, see sheet A-2 Floor plans. <br /> 6. The storage area under the stairs in the Piano Retail space <br /> shauld be shown protected as for one-hour construction. Sectian <br /> 1003.3.3.9. <br /> •"Revised, see sheet A-2 Basenent plan and <br /> floor plans. <br /> ACCESSIBILITY: <br /> 1 . The van-accessibie parking tall should be shown to be a <br /> minimum of 8 feet wide with an 8-foot wide acr,ess aisle adjacent <br /> to it (the other "standard" access aisle should be shown as 5 feet <br /> minimum►. Section 1107.2.2. <br /> ""Revised, s�e sheet A-1 Site plan notes. <br /> 2. Curb cuts should be shown in the sidewalk surrounding the <br /> building for accessible travel. Section 11-6.4.7. <br /> "Revised, see sheet A-1 Site plan. <br /> 3. Curbs, guardrails or raised 'bump'-type detectable warning <br /> surfaces should be provided where the accessibie route of travei <br /> crosses or adjoins vehicular areas. Section 1106.4.8 & 11-6.17. <br /> ""Revised, see sheet A-1 Site plan. <br /> 4. The following daors should be p•ovided with the proper <br /> maneuvering clearance as noted in SFction 1106.10.3:Doors <br /> N2,7,9,20,22.24 & 25. <br /> ""Revised, see sheet A-2 Floor plan revisions <br /> and dimensions. <br /> 5. The showers should either comply as transfer or roll-in type <br /> - elevations should be provided. Sections 1105.2.1 & <br /> 1106.11 .10. <br /> "*Revised, see sheet A-2 Floor pian revision and notes. � <br />