My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4809 EVERGREEN WAY CLUBHOUSE GRILL 2018-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
4809
>
CLUBHOUSE GRILL
>
4809 EVERGREEN WAY CLUBHOUSE GRILL 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2018 2:41:15 PM
Creation date
2/9/2017 4:32:18 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
4809
Tenant Name
CLUBHOUSE GRILL
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> H. Exhaust outlet location _ Min.required Proposed <br /> 1. Exhaust outlel shall terminate above roof TyPe II 24 in. y� in. <br /> Distance from same or adjacent building 10 ft. �� ft. <br /> Distance above adjoining grede ��ft' ru n <br /> Distance from property line 10 ft. �� k. <br /> Distance from windows and doors �0 ft' — �� n' <br /> Distance from mechanical air intake 10 ft �u ft <br /> Distance of duct above adjoininy grade ai a�:ay �6 ft. ��' n' <br /> 1 <br /> � o„��L� 7.�a.�, �.�a�� . . <br /> I. Makaup air , � <br /> 1. Applicant shall provide makeup air not less than 90°�of the exhaust. I y l o� �fT"� <br /> 2. Makeup air system shail be electrically interiuciced with the erhaust system, such th^;[he n al;eup air system <br /> will operate when the exhaust system is in operation. Provide note on plan sheet no. • <br /> 3. Makeup air shall be provided by a mechanicai or gravity means of sufficient capacity. Windows and door <br /> openings shall not be used for the purpose of providing makeup air. <br /> 4. If more than 2500 cfm suppiied to the space other than the hood, provide heater capable of heating makeup air <br /> supplied to the space to 65 degrees F. Out ut BS�J_-- <br /> Heater model# Input BTU ____L- <br /> Heater CFM AFUE_-�- <br /> FAN I MOTORIZED �AMPER <br /> Make and modei CT 10 H.P. ?� Recommended air velocity, b00 ipm <br /> Static pressure '- �3 sa in. at cfm Duct area req. =cfmI500 fpm l5 - ft.' <br /> Duct Dimension .��� _ , area 1�`�� R.= Duct Dimension req. _ _ <br /> /y/1 ) / �• y S Eff. DampBr-opening X =__ ft? <br /> Air veiocity =cimlarea � -- <br /> _ ._ I'�I�' .�(� — fpm / <br /> J. Siope of duct and cleanout access <br /> 1. Horizontal duct up to 75' long Min slope Y+ inlft proposed CJ in/ft <br /> More ttian 75' long Min slope 1 inlft ?roposed � inlft <br /> 2. Tight-fittin, cleanout doors shall be providecl at Total numbe,r proposed <br /> every change in ductwork direction <br /> K. Du.t enclosure <br /> 1. Ducts penetrating a ceiling, wall or floor shell be enclosed in a duct enclosure having fire rating per IBC table <br /> 601 from the point of penetration to the outside air. A duct may only penetrate exte�ior walls at locatio�s wnere <br /> unprotected openings are permitted by Table 704.8 of 2003 Seattle Building Code. <br /> 2. For code compliance purposes, it is acceptable to assume that ducts penetrating concrete, brick or steel <br /> ceilings, walis or floors shali requir�a 2-hour fire-r?sistive duct enclosure, and for others, it shall be 1 hour. <br /> Tya�or Min. Fire•Resistive <br /> Cons�rurtion Const Cf Enclosure Proposed Proposed Material and Construction <br /> I F.R., II F.R. 2 hour hr. _Zr"� � � � F I 2 F(,,.� �A� <br /> II, 111, IV, V 1 hour hr. <br /> (�� <br /> J <br />