My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5107 EVERGREEN WAY 2016-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
5107
>
5107 EVERGREEN WAY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2017 7:00:26 PM
Creation date
2/9/2017 7:00:00 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
5107
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
176
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. . i, � <br /> 24. Based upon 51,660 square Feet of T;pe V-I Hr., sprinklered construction, the fire flcw requirement is <br /> 2,000 gpm. <br /> 25. Fire Alarm System - An approved automatic fire detection system shall be provided as required by City <br /> Ordinance No. 1902-92, Chapter 16.76, of the F,verett Municipal Code. Plans fo: such system shall be <br /> submitted to the Fire Marshal for review and approval prior to installation. Submittal shall include cut <br /> sheets of all equipment intended for use. Appropriate trip tests, wimessed Ey a Fire DepaRment <br /> inspector, shall be performed, along with a certificate of completion, prior to final acceptance of the <br /> system. Fire alarm systems shall be installed according to NFT'A Standard 72. Fire alarm systems shall <br /> Ue installed under permit of the City of Everett Building Department. Electrical inspections and approval <br /> are required prior to calling for acceptance tests. Call (425) 257-8810 for permit information. <br /> 26. Fire Suppression (Sprinkler) System - An approved automatic suppression system shall be provided as <br /> required by City Ordinance No. 1902-92, Chapter 16.76, of the Everett Municipal Code. Plans for any <br /> such system shall be submitted to the Building Department and the Everett Fire Department for <br /> examination and approval. Such plans shall include plans for the underground mains that will supply the <br /> sprinkler system. Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA <br /> Standard 13. Underground piping shall be hydrostatically tested and flushed as established in NFPA <br /> Standard 24 for private fire mains. All such tests shall be witnessed by a Fire Department inspector. <br /> Call (425) 257-8123 to make an appointment for inspection. Contractors' materials and test certificales <br /> shall be submitted to the Everett Fire Department prior to issuance of any Certificates of Occupancy. <br /> Call (425) 257-8123 for more information. <br /> 27. 3ecurity Fence - Any security fence erected around the construction site shaL be located so as to not <br /> obstruct any existing hydrant, fire protection equipment, or Fire Department access. If Fire Department <br /> access is obstructed, gates or other openings shall be provided for access. <br /> 28. Fire Safetv - Fire safety practices during construction shall be in compliance with Article 87 of the <br /> Uniform Fire Code. <br /> 5 %� <br />
The URL can be used to link to this page
Your browser does not support the video tag.