My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6220 EVERGREEN WAY VALUE VILLAGE 2016-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
6220
>
VALUE VILLAGE
>
6220 EVERGREEN WAY VALUE VILLAGE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2017 5:07:59 PM
Creation date
2/9/2017 10:18:05 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6220
Tenant Name
VALUE VILLAGE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
144
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br />2. If a fire sprinkler system is not provided per item 1, the building must be of type <br />V-1-hour construction per table 5-B. <br />All construcdon must be one hour rated. Provide justifying test data for all <br />assemblies used. <br />3. If a fire sprinkler system is nct provided per item 1 vinyl soffit material cannot be <br />used per Sec. 1404.1 (allowed in VN buildings only). <br />4 between the s ock room and sales/office areastmust be one hour aPed per sec. <br />309.2.2. <br />5 <br />C� <br />Provide insulation R-values (R-11 Minimum for walls). <br />Guardrail spacing shall be 4" minimum sec. 509.3 <br />7. Provide under floor access and ventiladon to area under the observation room per <br />sec. 2317.3 and sec. 2317.7. <br />E� <br />� <br />Please provide dimensions and detail for the accessible dressing booth. <br />Indicate roof access <br />10. Overflow drains aze required for new drain locations per sec. 1506.3. <br />11. Please indicate safety glass per sec. 2406.4. <br />12. Please do not provide an exit light at door #4 (exits cannot pass through storage <br />rooms). <br />Please provide an exit light at door 1i3. <br />Upon resubmittal of the drawings, your application will be given priority snd plan <br />review will recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to <br />ensure that the proposed structure will be constructed in compliance w�i[h all adopted <br />codes. <br />Sincer � <br />�e S. Mc all <br />ssociate Engineer/Building <br />Jm:jd:pcB5004fi <br />
The URL can be used to link to this page
Your browser does not support the video tag.