Laserfiche WebLink
CHECK NEW CONDITION WITH ITEM 1-BDTI0GOL6C WEIGHT= 11981bs <br />UNITS WIDTH = 37" UNITS LENGTH = 64" <br />MUST ENGAGE AT LEAST (2) 2X8 ROOF JOIST <br />USE SLEEPER TO TRANSFER LOADS <br />ASSUME LOAD IS TRANSFERRED @ ENDS OF UNIT BY SLEEPER <br /># OF ENDS = 2 <br /># OF JOISTS USE TO TRANSFER = 2 <br />P=1198/2/2= 299.50 Ibs <br />TOTAL LOAD = EXISTiNG + NEW CONDITON = 296 + 299.50 = <br />Mall= 13.24 k-ft <br />M=P * a 0.79 k-ft <br />� ��II »> M OK <br />CHECK NEW (._.NDITION WITH ITEM 2-BDT0900L6C WEIGHT= 1193 Ibs <br />UNITS WIDTH = 37" UNITS LENGTH = 64" <br />MUST ENGAGE HT LEAST (2) 2X8 ROOF JOIST <br />USE SLEEPFR TO TRANSFER LOADS <br />ASSUME LOAD IS TRANSFERRED @ ENDS OF UNIT BY SLEEPER <br />#OFEND5=2 <br /># OF JOISTS USE TO TRANSFER = 2 <br />P=1193/2/2= 298.25 Ibs <br />TOTAL LOAD = EXISTING + NEW CONDITON = 296 + 299.50 = <br />Mall= 13.24 k-ft <br />M=P * a 0.79 k-ft <br />Mall »> M OK <br />595.50 ibs <br />594.25 Ibs <br />