My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8120 EVERGREEN WAY BASE FILE 2018-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
8120
>
BASE FILE
>
8120 EVERGREEN WAY BASE FILE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2018 1:12:57 PM
Creation date
2/10/2017 12:53:59 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8120
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
19. Security Fence - E;ny security fence erected around tha construction site shall be <br />located so as to not obstruct any existing hydrant, fire protection equipment, or Fire <br />Department access. If Fire Department access is obstructed, gates or other <br />openings sha�! be provided for accas�. <br />20. Premise Ideniification - Premises shall be clearly identified by the correct address <br />at the street entiy. Buildings shall he clearly identified so as to be visible and <br />legible from the access road. Indi�idual aFartm�:��., and suites, where applicable, <br />shall be clearly and legibly identifi�ad from the access roed. <br />21. PREMISE iDE�lTIFICATIOP! AND ALL REQL'IRE� FIRE DEPARTMENT <br />ACCESS ROADS AND FIRE HYDRAMTS SHALL BE IN SERUICE PRIOR TO <br />CUMMENGE�9ENT UF t;ONSTG�UC't ION. <br />22. A fire hydrant is required within 2�0 driving feet, but not closer than 50 feet, of <br />every structure. Location of ;ns hydrant(s) shal! be approved by the Fire Marshal. <br />23. Fire Flow - Fire flow requiremenis for this stnicture ara 1,50Q gpm. <br />'?4. Fire Alarm Svstem, - An approved automatic fire detection system shail be provided <br />as required by G'ity Ordinanr,e �lo. 19C::-a2, Chapter 16.76, of the Everett <br />Nlunicipal Code. <br />Plans for such �ystem sf�all be submiited to the Fire Nlarsha! for review and <br />approval prior to installation. Submittal st�all include cut sheets of all equipment <br />intended for use. A.ppropriate trip tests, witnessed by a Fire Department inspector, <br />shall be perform� d, along witn a certificate of completion, prior to flnai accepiance <br />of the system. <br />Fire �larm systenis shall be installed according to NFPA Standard 72. Installation <br />of fire alarm components, including basic wiring, may not commence before plans <br />are approved by �he Fire Department Plan Reviewer. Fire alarm dravdings must be <br />prafessionally i�enaered, in sufficient deiail, and must be internally consistent. <br />Riser diagr��!ns must match installation plans and lead calculations. Components <br />must he listed and approveci for use together. Changes to plans must include new <br />drawings and c2lculations and rn�ist be aaproved by the Fire Department Plan <br />Reviewer orior to installatiori: F'ire ala� ni installation is subject to field inspection by <br />a Fire Department Inspectur. An approved set o� plans and tne Building <br />Uepartment electrical permit must be press�i for uny installation inspection. <br />Fire alarm systems shall be �nstalfed under permit of the City of Everett Building <br />Deparfment. Electrical inspections and aparoval are required prior to calling for <br />acceptance test�. Call (425� 257-8810 for perrnit information. <br />
The URL can be used to link to this page
Your browser does not support the video tag.